5.2 FRONT PANEL CONTROLS
5.2.1 RESET BUTTON
Depressing the Reset button resets the Signal Monitor after it has been triggered by a fault. The monitor
will remain in the reset mode only if the fault condition has been restored to normal. In the event of a
monitor hardware or firmware fault (DIAGNOSTIC) the Reset button may not reset the monitor. A
power-up restart may be required.
The Reset button also provides control of the Diagnostic Display mode. For a complete description of
Diagnostic Display operation see Sections 3.10.