- 27 -
ENGLISH
ELECTRONIC EQUIPMENT
REMOTE IGNITION
On the circuit board, there is an input)
supplementary thermostat clean contact *) that can be used for
remote ignitions via external thermostats.
These devices must be installed by authorized CAT via an
optional cable, code 640560.
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR
2032 battery).
For more detailed information, please contact the DEALER
who has performed the rst 1st ignition.
SAFETY DEVICES
THERMOCOUPLE:
placed at the smoke outlet to detect the temperature. Turns the
stove on and off and controls its operation based on de ned
parameters.
AIR FLOW SENSOR:
placed in the air inlet channel. This intervenes if an anomaly
is detected in the combustion air ow and causes insuf cient
circulation in the smoke ducts.
SAFETY THERMOSTAT:
trips when the temperature inside the stove is too high.
It stops pellet loading, causing the stove to go out
(see alarm A09 on pg. 29).
ELECTRONIC CIRCUIT BOARD
BACKUP
BATTERY
*
VOLUME METER
SERIAL
DISPLAY
SMOKE
VENTILATOR
SCREW
ALLARM
1
ALLARM
2
ENTRY
SECURITY
SCREW
CONTACT
SECURITY
SCREW
SMOKE PROBE
NTC 300°C PROBE
ANCILLARY THERMOSTAT
ENV. PROBE
PRESSURE TRANSDUCER
SMOKE VENT. ENCODER
INLETS
SENSOR LEVEL PELLET
FAN CONTROL
BOARDS
EXCHANGER
3
EXCHANGER
1
EXCHANGER
2