EasyManua.ls Logo

EdilKamin LILIA User Manual

EdilKamin LILIA
77 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
- 1 -
LILIA
I Installazione, uso e manutenzione pag. 2
UK Installation, use and maintenance pag. 14
F Installation, usage et maintenance pag. 26
E Instalación, uso y mantenimiento pag. 38
D Installations-, Betriebs- und Wartungsanleitung pag. 50
NL installatie, gebruik en onderhoud pag. 62
Question and Answer IconNeed help?

Do you have a question about the EdilKamin LILIA and is the answer not in the manual?

EdilKamin LILIA Specifications

General IconGeneral
ModelLILIA
CategoryStove
BrandEdilKamin
MaterialSteel
Diameter of smoke outlet120 mm

Summary

Safety Information

Declaration of Conformity

Operating Features

Notes on Fuel

Heating Specifications

Electrical Specifications

Safety Devices

Thermocouple

Measures smoke temperature and controls ignition/operation stages.

Air Flow Sensor

Detects incorrect combustion air flow, causing pressure issues.

Safety Thermostat

Trips if stove temperature is too high, stopping pellet loading.

Fuse

Protects the stove, with a spare fuse available.

Assembly and Installation (Dealer)

Compatibility Check With Other Devices

Electrical Connection Check

Fire Safety Distances and Location

Air Intake

Smoke Outlet

Coverings

Covering Parts List

Lists all components for the ceramic covering.

Covering Installation

Step-by-step instructions for fitting ceramic coverings.

Instructions to Apply the Gasket to the Ceramic Tiles

Interface

Left Knob (SX)

Controls power adjustment and temperature setting.

Right Knob (DX)

Adjusts room air flow for internal cooling.

Panel On/Off Key

Turns the stove on or off.

Panel A/M Key

Switches between manual and automatic operating modes.

Panel "Hourglass" Key

Used for setting programmed on/off times.

Operation

Before Ignition

Checks and preparations required before starting the stove.

Screw Feeder Loading

Procedure for refilling the screw feeder after it empties.

Ignition

Step-by-step guide for starting the stove.

Manual Ignition

Operating Modes

Switching Off

Weekly Time Programmer Built Into Panel

Setting the Clock

How to set the current time and day on the programmer.

Enabling Programmes

How to activate or deactivate programmed ignition cycles.

Setting a Programme (e.g. Pr01)

Detailed steps for configuring ignition and shutdown times.

Remote Control

Advice in the Event of Problems

Possible Causes of Shutdown

Advice in the Event of Problems

H1) Low Pressure Alarm

Checks for issues causing insufficient combustion air flow.

H2) Smoke Expulsion Motor Failure

Troubleshooting smoke extraction motor faults.

SF (H3) Flame Stop

Diagnosing reasons for flame absence.

AF(H4) Ignition Failed

Troubleshooting ignition failures.

H5) Power Failure Stoppage

Checking electrical connections for power issues.

H6) Thermocouple Failure

Diagnosing thermocouple faults or disconnections.

H7) Excessive Smoke Temperature

Identifying causes for high smoke temperature shutdowns.

Servicing

Daily Cleaning

Routine cleaning procedures for the stove.

Every Season (by the Dealer)

Annual maintenance tasks performed by a qualified dealer.

Optional Extras

Parts List

Parts List

Related product manuals