EN Installation, use and maintenance page 2
LILLE 5
LILLE 8
Pellet stove

Questions and Answers

  • H
    Haley WhiteAug 12, 2025
    What to do if EdilKamin LILLE 5 shows error H04?
    • T
      Terry JordanAug 12, 2025
      If your EdilKamin stove displays error H04, indicating no flame, first check that the grate is seated properly and is clean. Also, verify that there are pellets in the tank and grate. If these steps don't resolve the issue, you can try to use a piece of solid paraffin to light the stove, but contact the technician first.
  • W
    William HernandezAug 18, 2025
    Why does my EdilKamin LILLE 5 show H01 error?
    • S
      Shane LopezAug 18, 2025
      The H01 error on your EdilKamin Stove indicates that the combustion air intake is below the set level. To resolve this, ensure that the combustion chamber door is closed. Additionally, perform regular maintenance on the stove and check that the smoke discharge and combustion air ducts are clean.
  • R
    Richard MorrowAug 26, 2025
    What to do if my EdilKamin LILLE 5 shows error H03?
    • E
      Elizabeth ChangAug 27, 2025
      If your EdilKamin Stove displays error code H03, it means that the thermocouple detects a smoke temperature lower than the set value, interpreting it as the absence of flame. To solve this, check that there are pellets in the tank. If the issue persists, contact the technician.
  • X
    xdicksonSep 2, 2025
    What to do if my EdilKamin LILLE 5 is showing error H11?
    • H
      heathrobinSep 2, 2025
      If your EdilKamin Stove is showing error H11, ensure the stove and flue are clean. If the issue persists, contact the technician.

EdilKamin LILLE 5 Specifications

General IconGeneral
TypePellet stove
Tank capacity15 kg
Flue Gas Outlet Diameter80 mm
Fuel TypePellets
Width460 mm

Related product manuals