The unit
makes a
noise
The unit is not on a smooth surface.
Place the unit on a hard and at
surface.
The com-
pressor
does not
work
The overheating protection has been
triggered.
Wait 3 minutes until the tem-
perature has dropped, and then
restart the unit.
The
remote
control
does not
work
The distance between the remote
control and the unit is too large.
Decrease the distance and point
the remote control directly at the
unit.
The battery is dead. Replace the battery.
The unit
displays
'E1' on the
display
The pipe temperature sensor is
wrong.
The pipe-temperature sensor and
the corresponding circuit requires
inspection. Contact customer
service
The unit
displays
'E2' on
the dis-
play
The room temperature sensor is
wrong.
The room temperature sensor and
the corresponding circuit require
inspection. Contact customer
service
9. Technical specications
Model Kaya, Item No. 2521
Recommended working area, m
2
14-30
Cooling capacity Btu/hr 9000 (2630 W)
Timer 1-24 hrs
Power supply 220-240 V, 50 Hz
Dehumidication capacity L/day 24
Power consumption (cooling) 1010 W
Nominal current A (cooling) 4,4
COP 2,3
Air ow, M
3
/hrs 350
Sound level dB (A) ≤ 65
Operating temperature 7-35 °C
Refrigerant R290
Net weight 22 kg