43
Ambient Sensor Monitoring - The temperature is monitored via the
equipment’s ambient temperature sensor.
Note: When this monitoring mode is active, will appear on the display. In this
operating mode, the Ambient Sensor will also perform Antifreeze/Overheating
Protection (see 3.6).
Floor Probe Monitoring - Temperature is monitored by the Floor
Probe.
Note: When this monitoring mode is active, will appear on the display. In
this operating mode, in addition to monitoring the temperature, the Probe will
also perform Antifreeze/Overheating Protection (see 3.6), preventing the floor
from exceeding the defined maximum/minimum temperatures set, thus avoiding
overheating/overcooling of the floor.
Ambient Sensor Monitor + Floor Probe - The temperature is
monitored via the equipment’s ambient temperature sensor and
the Floor Probe, preventing overheating/overcooling of the floor
by preventing the floor temperature from exceeding the maximum/
minimum temperature limits set.
Note: When this monitoring mode is active, will appear on the display. In
this mode, the temperature will be monitored by the Ambient Sensor and the
Probe will perform Antifreeze/Overheating Protection (see 3.6), preventing the
floor temperature from exceeding the defined maximum/minimum temperature
limits, thus avoiding overheating/overcooling of the floor.
3.9 Valve Protection (Valve protection system in hydraulic system)
Press or to select the desired option (Enabled or Disabled). Press
OK to confirm and exit or to go back (Default setting: Disabled).
Note: This menu only appears when the Hydraulic option is selected under “type of
installation” (3.2). This function, while in inactivity periods (summer) will actuate daily
the solenoid valves for one minute, in order to avoid blockages due to lack of use (only
when the chronothermostat is switched off.