UPDATE STEPS:
1. Begin by powering o the batteries receiving the update via the circuit breaker on the front of
the unit.
2. Adjust the battery DIP switches to address 0 (all DIPs down, see image below).
3. Remove all inter-battery communication cables from the batteries in parallel and set one to
the side for the update.
DIP switch address 0
NOTE: Ensure all communication cables, aside from the update cable, are disconnected from the
battery receiving the update!
Battery parallel communication cables

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EG4 LIFEPOWER4 48V and is the answer not in the manual?

EG4 LIFEPOWER4 48V Specifications

General IconGeneral
Capacity100Ah
ChemistryLiFePO4
Output Voltage48V
Communication InterfaceRS485, CAN
Protection FeaturesHigh temperature, Low temperature
Cycle Life>6000 cycles @ 80% DOD