EasyManuals Logo

EGO LB6000 User Manual

EGO LB6000
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Troubleshooting
Problem
Possible Cause
Fault Position
Test & Solution
Press the boost button/depth
adjusting knob when the
blower runs, the air velocity
and the volume doesn’t
change
PCBA or
switch
assembly
is
broken
PCBA in the duct
housing
or switch in
the handle housing
Following the
procedure in the
diagnosing section to test the
PCBA, If it is broken, r
eplace
PCBA
. If PCBA works fine, test
the switch and replace the switch
assembly if it is not working.
The air velocity and the
volume are decreased
compared
with normal use
The fan in the
duct is over
-worn
Fan in Ducted
assembly
Open the housing set,
take off
the fan baffle
and check the fan.
If the fan is over
-worn, replace
the
motor and ducted assembly.
4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EGO LB6000 and is the answer not in the manual?

EGO LB6000 Specifications

General IconGeneral
BrandEGO
ModelLB6000
CategoryBlower
LanguageEnglish