What to do when …
Problem RemedyCause
Filter does not empty, no
wet/dry function
Filter does not fill up, no
wet/dry function
Properly install o-ring,
replace if necessary.
Clean collar and disk.
Properly install o-ring,
replace if necessary.
Place filter in vertical
position.
O-ring on small support
worn out, not installed or
improperly installed.
Filter in slanted position.
Bypass aperture in wet/dry
control mechanism soiled.
Clean bypass.
Open output tap complete-
ly.
Lay out tube without kinks.
Clean tubing.
Output tap on integrated
double tap connector is
closed or not completely
open.
Outlet tube is bent or
soiled.
Worn out or wrongly instal-
led o-ring on floating con-
trol valve.
Collar and disk on floating
control valve soiled.