EasyManua.ls Logo

EHEIM Professionel 4e+ 350 - Safety Instructions and Operation; Terminology of Display; Connecting and Initial Operation; Flow Rate Adjustment

EHEIM Professionel 4e+ 350
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E
nglish
Safety instructions
FOR HOUSEHOLD USE ONLY! WARNING! RISK OF ELECTRIC SHOCK! This pump has not been investigated for
use in swimmung pools areas! DO NOT RUN DRY!
Danger! Prior to carrying out works in the water, disconnect all electronic devices installed in the water from
the mains. Assure that no water intrudes into the filter’s plug connections.
The device’s power supply line cannot be replaced. In case of cable damage, the device must no longer be
operated. Contact your specialist dealer or an EHEIM service center or visit www.eheim.com
Service / programming
Flowrate plus
Flowrate minus
Warning indicator
Output max
Automatic mode
off / programming
Service indicator
Flowrate indicator.
S
1. Terminology of display
Set the locking lever toON“. Rapidly press the suction aid several times consecutively until the filter tank automatically
fills with water.
Plug in the power supply unit at the pump head. Plug in the power cable. The filter starts the automatic self-bleeding
process (auto air out). This may take several minutes.
To accelerate the self-bleeding process, press the suction aid several times. The filter starts the automatic self-calibration
process (auto calibration).
2. How to connect and put into operation
A Flow rate reduction:
Caution:
Do not adjust the flow rate via the adapters gate valve!
Automatic mode (factory setting) = 6 green LEDs
are illuminated.
Shortly press the“ button
. One LED
is extinguished per each pushbutton stroke.
Minimum flow rate: 1 green LED
is illuminated.
B Flow rate increase:
Shortly press the+“ button
. The orange LED
is illuminated.
Maximum flow rate. The pump no longer automatically re-adjusts itself.
3. Reducing / increasing the FLOW RATE
6
Automatic mode: 1 to 6 green LEDs
are illuminated (Fig.: factory settings).
Shortly press the „S“ button
once. Only the red LED
is illuminated.
The indicator counts. Per each green LED = 1 month remains until the next cleaning with constant pollution increase.
After 10 seconds, the indicator automatically returns to the automatic mode. 1 to 6 LEDs
are illuminated.
4. Service display
A Activation of 12 hour bio function:
Adjust the flowrate of the SECOND 12 hours (see chapter 3A/3B).
5. Switching on / off the 12-HOUR BIO-FUNCTION

Related product manuals