2. Pull the impeller
j
out of the motor housing.
3. Gently press the power controller
f
apart and remove it from the
pump basket.
4. Using a brush, clean all components under running water. Remove lime
scale deposits with 10 % citric acid
5. Install the pump again in reverse order.
When assembling, make sure that the washer disc
i
is correctly inserted
into the motor housing.
streamON+ 6500 / 9500 (⌦G)
1. Press both latches simultaneously and remove the pump basket
h
from the motor housing.
2. Pull the power controller
g
out of the motor housing.
3. Pull the impeller
j
out of the motor housing.
4. Using a brush, clean all components under running water. Remove lime
scale deposits with 10 % citric acid
5. Install the pump again in reverse order.
When assembling, make sure that the bearing bushings
k
are inserted
correctly in the pump basket and in the motor housing.
7. Clearing faults
Attention! Electrocution!
Before clearing faults, remove the mains plug of the pump.
Faults Possible cause Remedy
Pump does not start No mains voltage Check the mains
voltage
Check the supply line
Pump does not pump Mains plug is not inserted Insert the mains plug in
the mains socket
Impeller is blocked Clean the pump

Related product manuals