8
the alarm with the red light flashing, the others are
probably satisfactory).
2. LOW BATTERY & OTHER BEEPS:
(1) If the battery is correctly connected and the unit
has beeped for over 20 minutes the battery is probably
depleted. Obtain a new battery, disconnect the mains,
then remove the Alarm and replace the depleted battery.
(2) If the Ei146RC beeps without the red light flashing at
the same time, the chamber is defective. See ‘Cleaning
your Alarm’ section.
(3) If the green mains light is on and replacing the battery
or cleaning the unit has not stopped the beeps, a fault
may exist. Disconnect the mains first and replace the
unit - see “Alarm Removal” section.
3. INTERCONNECTED ALARMS DO NOT ALL
SOUND:
(1) Hold test button for 10 seconds after first Alarm has
sounded to ensure signal is transmitted to all units.
(2) One or more of the connections may not be correctly
connected. We recommend you consult a qualified
electrician.