Instruction Manual
for the
Aquameter
TM
Series
Multiparameter Water Quality
Meters, Probes, Utilities & Accessories
(Software Version 3.00 and above including Optical DO & Depth Measurement)
Document No. 10401-00188
Revision: M
Date: February 16, 2011
Aquaread Ltd
Kent Innovation Centre
Thanet Reach Business Park
Millennium Way
Broadstairs
Kent
CT10 2QQ
ENGLAND
Phone: +44 1843 609 692
www.aquaread.co.uk
P.O. Box 4, 6987 ZG Giesbeek
Nijverheidsstraat 30,
6987 EM Giesbeek,
The Netherlands
T +31 313 880 200
E info@eijkelkamp.com
I www.eijkelkamp.com
M185701E

Table of Contents

Questions and Answers

  • C
    Cameron LaneAug 19, 2025
    Why are pH readings inaccurate on EIJKELKAMP Measuring Instruments?
    • J
      James SanchezAug 19, 2025
      Slow, inaccurate, or unstable pH and ORP readings, or the inability to calibrate your EIJKELKAMP Measuring Instruments can occur for several reasons: * The electrodes may need recalibrating, so recalibrate them. * The electrodes may need cleaning. * The electrodes may have been allowed to dry out. * The electrodes may be damaged and need replacing. * Water may have entered the electrode socket because the electrode is loose. Remove the electrode, blow out the socket with compressed air, and leave the probe and electrode in a warm place for at least 48 hours to dry out.
  • L
    Linda KnightAug 21, 2025
    Why are dissolved oxygen readings inaccurate on EIJKELKAMP Measuring Instruments?
    • G
      gkingAug 21, 2025
      Inaccurate or unstable dissolved oxygen readings on your EIJKELKAMP Measuring Instruments can stem from several causes: * There may be insufficient flow across the Galvanic DO membrane. Ensure a constant water flow whilst taking readings (does not apply to AP-900 & AP-1000). * The DO electrode may need calibrating, so recalibrate it. * The DO membrane may be dirty, so clean it. * The DO membrane may be worn out or damaged, so replace the DO membrane cap. * Calibration may have been carried out at an extreme temperature. Recalibrate at a temperature as close to the sample temperature as possible.
  • P
    Patricia PhillipsAug 23, 2025
    Why are EC readings inaccurate on EIJKELKAMP Measuring Instruments?
    • R
      Robert KramerAug 23, 2025
      Inaccurate or unstable EC readings, or Error 09 during calibration on your EIJKELKAMP Measuring Instruments, can be due to: * Missing Probe Sleeve: EC will not work without the whole Probe Sleeve fitted. * Insufficient sample depth: Ensure the sample level reaches the minimum depth line on the outside of the Aquaprobe. * Trapped air bubbles: Tap and swish the Aquaprobe to dislodge them. * Loose Probe Sleeve: The Probe Sleeve must be absolutely rigid with respect to the Probe Body for correct EC operation. If you can move the Probe Sleeve to and fro whilst holding the Probe Body, tighten the four screws then recalibrate. * The EC electrode may need recalibrating, so recalibrate it. * Dirty EC electrode: Clean the EC electrode then recalibrate.
  • S
    Samantha NguyenAug 27, 2025
    What to do if AquaLink software can't find EIJKELKAMP Measuring Instruments?
    • S
      Stacy HoltAug 28, 2025
      If the AquaLink software cannot find the Aquameter, it could be due to: * Improperly installed USB drivers: Reinstall the USB drivers carefully following the instructions. * A problem with the USB socket on the PC: Try an alternative socket.
  • X
    xmonroeAug 29, 2025
    How to fix GPS on EIJKELKAMP Measuring Instruments?
    • J
      Jerry TateAug 30, 2025
      If the GPS Aquameter does not show a position fix, it probably does not have a good enough view of the available satellites. Ensure there are no obstructions between the Aquameter and the open sky. Remember, GPS does not work indoors.
  • U
    ubrooksSep 1, 2025
    What does ERROR 02 mean on EIJKELKAMP Aquameter?
    • D
      Debbie BarnettSep 1, 2025
      ERROR 02 on the Aquameter screen (AP-900 & AP-1000 only) indicates that the Optical DO electrode needs calibrating or the cap needs replacing. Perform a full DO calibration, first at DO Zero then at 100% DO. If that does not cure the problem, replace the Optical DO Cap.
  • K
    Kaylee HoodSep 3, 2025
    What to do if EIJKELKAMP Measuring Instruments can't find Aquaprobe?
    • K
      Katherine MccannSep 3, 2025
      If the Aquameter cannot find the Aquaprobe, there is probably a poor connection. Switch the Aquameter off, disconnect the Aquaprobe plug, ensure there is no debris or moisture in the plug, then re-connect the plug ensuring it is fully inserted and that the screw collar is fully tightened.
  • D
    Debra HardySep 5, 2025
    Why doesn't 'USB CONNECTED' appear on EIJKELKAMP Aquameter?
    • K
      Katie JenningsSep 5, 2025
      If the ‘USB CONNECTED’ message does not appear on the Aquameter when connected to a PC, it could be due to: * Dead or incorrectly fitted batteries: Check you have fresh batteries fitted and that they are inserted the correct way round. * A problem with the USB socket on the PC: Try an alternative socket.
  • R
    randersonSep 7, 2025
    What does ERROR 01 mean on EIJKELKAMP Aquameter?
    • D
      Daryl GreenSep 7, 2025
      ERROR 01 on the Aquameter screen indicates that the pH electrode has dropped below 85% efficiency. Try cleaning the pH electrode and re-calibrating. If that does not cure the problem, replace the electrode.
  • H
    Heather BuckSep 9, 2025
    What does ERROR 07 mean on EIJKELKAMP Aquameter?
    • C
      Christian ThorntonSep 9, 2025
      ERROR 07 on the Aquameter screen indicates that the Aquaprobe has stopped responding to requests for data from the Aquameter. Check the Aquaprobe plug is fully inserted. Cycle the power to reset the Aquaprobe.

Summary

Battery Installation and Care

Taking Measurements

What Does It All Mean?

Explanation of measurement parameters and their units.

Temperature Compensation

Explains how temperature affects measurements and automatic compensation.

GPS Reception

Details how the GPS receiver works and requirements for signal acquisition.

Memory Mode

Manually Saving Readings

Steps for saving current readings with a memory tag.

Recalling and Viewing Saved Readings

How to access and review previously saved measurements.

Automatic Data Logging

Setting up the meter to automatically record data at intervals.

Setting Units of Measurement

RapidCal Calibration Method

Using RapidCal

Step-by-step guide to performing the RapidCal calibration.

Calibration Error Codes

Resetting to Factory Calibration Defaults

General Probe Maintenance

pH;ORP Electrode Calibration and Maintenance

Calibrating pH

Errors During Calibration

pH Electrode Efficiency

Calibrating ORP

DO;EC Electrode Calibration and Maintenance

Calibrating the DO;EC Electrode

General procedure for calibrating the DO and EC sections.

Calibrating the DO Zero Point

Calibrating the DO 100% Saturation Point in Moist Air

Replacing the Galvanic DO Electrode Membrane Cap

Replacing the Optical DO Cap (AP-900 & AP-1000 only)

Calibrating EC

Verifying EC Calibration

Turbidity Electrodes Calibration and Maintenance

Calibrating the Turbidity Electrodes

Turbidity Zero Point Calibration

Verifying Turbidity Zero Point Calibration

Calibrating the Turbidity 1000 NTU Point

Verifying Turbidity 1000 NTU Point Calibration

AquaLink PC Software

Software Installation

Instructions for installing the AquaLink software on a PC.

Driver Installation

Steps for installing necessary drivers for PC communication.

Uploading Data From Your Aquameter

Exporting Text Reports

Exporting Excel Files

Exporting Google Files

Specification

METERS (V3.XX software)

Technical specifications for Aquameter models AM-200 and AM-100.

PROBES SPECIFIC

TROUBLESHOOTING

Meter Power and USB Connection Issues

Solutions for meter not turning on or USB connection problems.

Aquaprobe Communication and GPS Problems

Troubleshooting Aquaprobe detection and GPS signal issues.

Calibration and Sensor Reading Errors

Resolving calibration errors and inaccurate sensor readings.

Battery and Physical Issues

Addressing battery leakage and general physical problems.

Operation

Flowcell Troubleshooting