EasyManua.ls Logo

EINHELL NEW GENERATION NHR 130 - User Manual

EINHELL NEW GENERATION NHR 130
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
NHR 130
Art.-Nr.: 41.404.37 I.-Nr.: 01026
Bedienungsanleitung
Hochdruckreiniger
Operating Instructions
High-Pressure Cleaner
Mode dʼemploi
Nettoyeur haute pression
Gebruiksaanwijzing
hogedrukreiniger
Istruzioni per lʼuso
Idropulitrice

Betjeningsvejledning
Højtryksrenser
Instrukcja obsługi
Myjka wysokociśnieniowar
Használati utasítás
nagynyomású tisztító
Bf
Naputak za uporabu
Visokotlačni čistač
,
Uputstvo za upotrebu
Peraã pod visokim pritiskom
Das Gerät nicht in Betrieb nehmen, ohne die
Gebrauchsanleitung gelesen zu haben!
Please read these instructions carefully before
installing and operating the high-pressure cleaner!
Ne mettez pas lʼappareil en service sans avoir lu ce
mode dʼemploi !
Het toestel niet in bedrijf stellen zonder de
gebruiksaanwijzing te hebben gelezen!
Non mettere in funzione lʼapparecchio prima di
avere letto le istruzioni per lʼuso!

Tag ikke højtryksrenseren i brug, før du har
læst betjeningsvejledningen!
Nie wolno uruchamiać urządzenia bez przeczytania
instrukcji obsługi!
Anleitung NHR 130_SPK1:Anleitung NHR 130_SPK1 20.12.2006 14:46 Uhr Seite 1

Questions and Answers

  • M
    Matthew LewisAug 15, 2025
    Why is there a loss of pressure in my EINHELL NEW GENERATION NHR 130 Pressure Washer?
    • E
      Erica HallAug 15, 2025
      A loss of pressure in your EINHELL NEW GENERATION Pressure Washer can occur if the nozzle is worn, the valves are dirty or clogged, the valve seals are worn, the seals are worn, or the filter is clogged. To resolve this, change the nozzle; check, clean, or exchange the valves; check and/or exchange the valve seals and seals; and check and/or clean the filter.
  • B
    bpadillaAug 18, 2025
    What to do if the EINHELL NEW GENERATION NHR 130 Pressure Washer electric pump does not run?
    • J
      John HughesAug 18, 2025
      If the electric pump of your EINHELL NEW GENERATION Pressure Washer doesn't run when the switch is pressed, it could be due to a damaged plug, insufficient voltage, a locked pump, or a triggered thermal relay. Check the plug and fuses, manually turn over the motor, and allow the motor to cool down.
  • R
    Rebecca MillerAug 21, 2025
    Why is my EINHELL NEW GENERATION NHR 130 Pressure Washer running but not generating pressure?
    • S
      Sabrina MirandaAug 22, 2025
      If the electric pump of your EINHELL NEW GENERATION Pressure Washer runs but no pressure is generated, the intake filter might be clogged, air could be drawn in at the connectors, the inlet and outlet valves might be clogged or worn, or the nozzle hole diameter could be too large. Clean the filter, check the intake connection fitting and hose connectors, and clean or replace the valves. Also, check and replace the nozzle if necessary.
  • D
    dwrightAug 26, 2025
    How to reduce excess noise in EINHELL NEW GENERATION NHR 130?
    • M
      Melissa Lee MDAug 26, 2025
      Excess noise in your EINHELL NEW GENERATION Pressure Washer can be caused by air being drawn in, worn, dirty, or clogged valves, worn bearings, high water temperature, or a dirty filter. Check the intake lines; check, clean, and exchange the valves; check and/or exchange the bearings; lower the water temperature to below 60 °C; and check and/or exchange the filter.
  • D
    Dawn CarneyAug 28, 2025
    What causes irregular pressure in EINHELL NEW GENERATION Pressure Washer?
    • R
      rhuffmanAug 28, 2025
      Irregular operating pressure in your EINHELL NEW GENERATION Pressure Washer can be caused by air being drawn in, clogged and worn valves, or worn seals. Check the intake connectors, clean and replace the valves, and check and replace the seals.
  • S
    Stacy HarperAug 31, 2025
    Why does my EINHELL NEW GENERATION Pressure Washer motor suddenly stop?
    • B
      Briana RojasSep 1, 2025
      If the motor of your EINHELL NEW GENERATION Pressure Washer suddenly stops, it may be due to the thermal relay being triggered by overheating. Check the voltage, turn off the switch, and let the motor cool down for a few minutes.
  • J
    Jeremy GarrisonSep 4, 2025
    What to do if EINHELL NEW GENERATION NHR 130 Pressure Washer leaks from the pump head?
    • J
      Javier HernandezSep 4, 2025
      If water leaks from the pump head of your EINHELL NEW GENERATION Pressure Washer, it's likely due to worn seals or a worn O-ring on the seal set. Exchange the seal and the O-ring to resolve this issue.
  • G
    Gregory AlexanderSep 7, 2025
    Why is my EINHELL NEW GENERATION NHR 130 Pressure Washer pump dripping?
    • K
      Karl Fleming MDSep 8, 2025
      If your EINHELL NEW GENERATION Pressure Washer pump drips, it is because the seals are worn. Check and replace the seals by a professional repair shop.
  • L
    Lisa DownsSep 12, 2025
    What if water from EINHELL NEW GENERATION NHR 130 Pressure Washer is mixed with oil?
    • C
      Carlos AndersonSep 12, 2025
      If the expelled water from your EINHELL NEW GENERATION Pressure Washer is mixed with oil, it indicates that the sealing rings (water + oil) are worn. Check and/or exchange them.