do so, fit it between the suction hose and the
extractor port on the electric tool.
Set the switch (2) on the wet and dry vacuum cleaner
to position II, automatic mode. The moment you
switch on the electric tool, the wet and dry vacuum
cleaner switches on as well. When you switch off the
electric tool, the wet and dry vacuum cleaner
switches off as well after a pre-set delay.
6.5 Blowing
Connect the suction hose (11) to the blow connector
(10) on the wet and dry vacuum cleaner.
7. Cleaning, maintenance and ordering
of spare parts
Important!
Always pull out the mains power plug before starting
any cleaning work.
7.1 Cleaning
Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible.
We recommend that you clean the appliance
immediately after you use it.
7.2 Cleaning the appliance head (13)
Clean the appliance regularly with a damp cloth and
some soft soap. Do not use cleaning agents or
solvents; these may be aggressive to the plastic parts
in the appliance.
7.3 Cleaning the container (8)
The container can be cleaned with a damp cloth and
some soft soap or under running water, depending on
the amount of dirt.
7.4 Cleaning the filters
Cleaning the pleated filter (15)
Clean the pleated filter (15) regularly by carefully
patting it and cleaning it with a fine brush or hand
brush.
Cleaning the foam filter (16)
Clean the foam filter (16) with a little soft soap under
running water and allow it to air-dry.
7.5 Maintenance
At regular intervals and before each use, check that
the filters in the wet and dry vacuum cleaner are
securely fitted.
7.6 Ordering replacement parts
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
8. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
9
GB
Anleitung_BT_VC_1250_SA_SPK7:_ 24.09.2008 9:55 Uhr Seite 9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL BT-VC 1250 SA and is the answer not in the manual?

EINHELL BT-VC 1250 SA Specifications

General IconGeneral
BrandEINHELL
ModelBT-VC 1250 SA
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals