10. Possible causes of failure
Fault Cause Remedy
The equipment
does not work.
- No electrical voltage at the equip-
ment.
- The pump is frozen.
- The battery is not charged.
- The battery is not correctly connec-
ted.
- Check and thaw if necessary.
The motor starts but
there is no pressure
build-up.
- The water intake lter is clogged.
- Air intake in the water inlet.
- The discharge nozzle is too large.
- The water cock is closed.
- Clean the water intake lter.
(see 7.2.1)
- Check the supply hose and hose
connectors and replace if necessary.
- Check and replace if necessary.
- Turn open the water cock.
The operating pres-
sure is irregular.
- Air intake in the water inlet. - Check the supply hose and hose
connectors and replace if necessary.