EasyManua.ls Logo

EINHELL MK 2100 E - Technical Data

EINHELL MK 2100 E
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
- 25 -
8. Technical data
MK 2100 E MK 2300 E MK 2600 E
Mains voltage 220 - 240V ~ 50Hz 220 - 240V ~ 50Hz 220 - 240V ~ 50Hz
Refrigerant R410A R410A R410A
Refrigerant group L1 L1 L1
Coolant quantity 350g
(0.73 t CO
2
Äq.)
390g
(0.81 t CO
2
Äq.)
370g
(0.77 t CO
2
Äq.)
Rated cooling capacity (P
rated
) in kW 2.1 2.3 2.6
Recommended max. room size in m
3
50 65 80
Rated power consumption (P
rated
) in kW 0.805 0.88 0.996
Rated cooling capacity (EERd) 2.61 2.61 2.61
Energy efficiency class A A A
Power consumption (P
TO
) in W 123 102.3 123
Power consumption (P
SB
) in W 0.95 0.95 0.95
Area of application room temperature 18 – 32 °C 18 – 32 °C 18 – 32 °C
Max. pressure (MPA) 4.2 4.2 4.2
Max. dehumidifier capacity l/h
(30°C / 80% RH)
0.8 1.0 1.0
Fan speed levels 2 + Automatic 2 + Automatic 2 + Automatic
Timer (in h) 1-12 1-12 1-12
Max. air throughput (m
3
/h) 370 355 375
Rated current consumption (A) 3.5 4.1 4.5
Compressor type Rotary piston Rotary piston Rotary piston
Compressor starting current RLA max.
(A)
18 19 20
Sound power level db(A) 65 65 65
Greenhouse warming potential
(GWP, kg CO
2
eq.)
2088 2088 2088
Exhaust air hose (Ǿ x L in mm) 127x1500 127x1500 127x1500
Housing dimensions WxDxH in cm 30.5 x 38.3 x 75.2 30.5 x 38.3 x 75.2 30.5 x 38.3 x 75.2
Anleitung_MK_2100_E_SPK7.indb 25Anleitung_MK_2100_E_SPK7.indb 25 25.09.2018 10:12:4125.09.2018 10:12:41