8.5 Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info
Replacement cutting unit Art. No.: 34.211.08
Replacement aerating unit, Art. No.: 34.211.09
9. Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
18
GB
Fault
Possible causes
Rectification
Motor does not start a) No electricity in plug
b) Cable defective
c) Switch, switch/plug block
defective
d) Connections to motor or
capacitor disconnected
e) Housing clogged
a) Check line and fuse
b) Check
c) Have machine checked by a
customer service center
d) Have machine checked by a
customer service center
e) If necessary adjust working depth.
Clean housing so that the roller can
run freely
Engine performance drops a) Soil is too firm
b) Housing clogged
c) Roller badly worn
a) Change working depth
b) Clean housing
c) Replace roller
Imprecise scarifying result a) roller worn
b) Wrong working depth
a) Replace roller
b) Correct working depth
Motor is running, roller is not
rotating
a) Toothed belt is torn a) By customer service workshop
10. Troubleshooting guide
Important notice! To protect the motor itis equipped with a thermal overload switch which cuts out
when overloaded and starts again automatically after a short cooling-down period.