EasyManua.ls Logo

EINHELL TC-PG 65/E5 - User Manual

EINHELL TC-PG 65/E5
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TC-PG 65/E5
Art.-Nr.: 41.526.10 I.-Nr.: 21022
13
D Originalbetriebsanleitung
Stromerzeuger
GB Original operating instructions
Power Generator
F Instructions d’origine
Générateur de courant
I Istruzioni per l’uso originali
Generatore di corrente
DK/ Original betjeningsvejledning
N Generator
S Original-bruksanvisning
Strömgenerator
CZ Originální návod k obsluze
Generátor
SK Originálny návod na obsluhu
Elektrický generátor
NL Originele handleiding
Elektriciteitsgenerator
E Manual de instrucciones original
Grupo Electrogeno
FIN Alkuperäiskäyttöohje
Generaattori
SLO Originalna navodila za uporabo
Električni generator
H Eredeti használati utasítás
Áramfejlesztő
RO Instrucţiuni de utilizare originale
Generator de curent
P Manual de instruções original
Gerador
PL Instrukcją oryginalną
Generator prądotwórczy
TR Orijinal Kullanma Talimat
Jeneratör
EE Originaalkasutusjuhend
Generaator
Anl_TC_PG_65_E5_SPK13.indb 1 26.01.2023 11:02:54

Questions and Answers

  • L
    Linda HahnAug 10, 2025
    What to do if my EINHELL TC-PG 65/E5 Portable Generator has no voltage?
    • Q
      qsweeneyAug 10, 2025
      If your EINHELL Portable Generator is showing too little or no voltage, consider these potential causes and solutions: * The overcurrent circuit-breaker may have triggered. If so, actuate the circuit-breaker and reduce the load from consumers. * A dirty air filter can also cause voltage issues. Try cleaning or replacing the air filter. * If the controller or capacitor is defective, contact your dealer.
  • B
    burnscourtneyAug 16, 2025
    Why won't the starter turn on my EINHELL TC-PG 65/E5 Portable Generator?
    • L
      Lee MurphyAug 16, 2025
      If the starter on your EINHELL Portable Generator isn't turning, the issue might be: * A discharged battery. Try charging the battery. * The battery might not be connected. Ensure the battery is properly connected.
  • W
    William HutchinsonAug 22, 2025
    What to do if the battery of my EINHELL TC-PG 65/E5 does not charge?
    • R
      Randall BrownAug 22, 2025
      If the battery on your EINHELL Portable Generator isn't charging, here are a couple of things to investigate: * Check for poor contact to the battery and clean the contacts. * Have the battery checked by an expert and replace it if necessary.
  • D
    Daniel ScottAug 28, 2025
    What to do if my EINHELL TC-PG 65/E5 Portable Generator engine does not start?
    • J
      James TaylorAug 28, 2025
      If your EINHELL Portable Generator's engine won't start, it could be due to several reasons. First, the automatic oil cut-out may not have responded. To resolve this, check the oil level and top up the engine oil if needed. Another possible cause is a fouled spark plug. Try cleaning or replacing the spark plug, ensuring the electrode spacing is 0.6 mm. Lastly, check if there's fuel in the generator. Refuel if necessary, and have the petrol cock checked.
  • T
    Theresa JordanSep 4, 2025
    How to fix a battery that does not charge on EINHELL Portable Generator?
    • J
      johnjonesSep 4, 2025
      If the battery of your EINHELL Portable Generator isn't charging, it might be due to poor contact to the battery. Try cleaning the contacts to ensure a good connection. Also, the 12 V safety trip may have been triggered. Check the function of the equipment using a different battery and actuate the 12 V safety trip.

EINHELL TC-PG 65/E5 Specifications

General IconGeneral
Generator typeSynchronous
Continuous power (230 V)5500 W
Max. power (230 V)6500 W
Rated current at 230 V23.9 A
Engine displacement389 cm³
FuelPetrol
Tank capacity25 L
Sound power level LWA96 dB(A)
Number of Outlets3
Starting SystemRecoil Start
Voltage230 V / 400 V
Frequency50 Hz
Engine Type4-stroke
Outlets2x 230 V~ / 1x 400 V