EasyManua.ls Logo

eisl DX12008 - User Manual

eisl DX12008
26 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
2
3/16
4
16
5
16
6
16
8
8/16
10
16
11
16
12
16
14
16
15
16
Montageanleitung
Überkopfbrause-Set DX12008
EL-BAD-ÜBS-DX12008_0919
DE
Montageanleitung .........................................................
Garantiekarte
CZ
Návod pro montáž .........................................................
Záruční list
ES
Instrucciones de montaje .............................................
Tarjeta de garantía
FR
Instructions de montage ..............................................
Bon de garantie
GB
Installation instructions ................................................
Warranty card
HR
Uputstvo za montažu ....................................................
Jamstveni list
HU
Szerelési útmutatás .......................................................
Garancialevél
NL
Montagehandleiding ....................................................
Garantiekaart
SI
Navodila za montažo .....................................................
Garancijski list
SK
Návod na montáž ...........................................................
Záručný list
17
Eisl Sanitär GmbH • Mattseer Landesstraße 8 • 5101 Bergheim (Austria) • info@eisl.at • www.eisl.at
17
Question and Answer IconNeed help?

Do you have a question about the eisl DX12008 and is the answer not in the manual?

Overview

This document describes the EISL DX12008 shower system, an overhead and hand shower combination designed for domestic use.

Function Description

The EISL DX12008 is a shower system that combines an overhead shower and a hand shower, allowing users to switch between the two functions. It is designed for use with pressure water heaters, instantaneous water heaters, central heating systems, and other hot water systems. The system includes a thermostatic mixer for precise temperature control, ensuring a comfortable and safe showering experience. The integrated diverter allows for easy switching between the overhead and hand shower functions.

Important Technical Specifications

  • Flow Pressure: Recommended 1.5 bar, maximum 6 bar.
  • Water Temperature: Maximum 80 °C.
  • Connection: 1/2" (approx. 1.9 cm) connections for water supply.
  • Dimensions:
    • Total height: approx. 1500 mm.
    • Distance from wall to overhead shower: approx. 700 mm.
    • Adjustable height for hand shower holder: approx. 1000 mm.
    • Overhead shower diameter: approx. 240 mm.
  • Thermostatic Mixer: Equipped with a safety stop at 38 °C to prevent scalding.
  • Materials: The product is made from high-quality materials, including chrome-plated surfaces.

Usage Features

  • Easy Installation: The manual provides detailed instructions and diagrams for installation, including mounting the shower rail, connecting the thermostatic mixer, and attaching the overhead and hand showers. Tools required for installation include screwdrivers, a drill, and an Allen key.
  • Temperature Control: The thermostatic mixer allows users to set and maintain a desired water temperature, with a safety stop at 38 °C to prevent accidental scalding.
  • Shower Selection: A push-button diverter on the mixer allows for easy switching between the overhead shower and the hand shower.
  • Adjustable Hand Shower: The hand shower holder can be adjusted in height along the shower rail to suit individual preferences.
  • Adjustable Overhead Shower: The angle of the overhead shower can be adjusted for optimal water coverage.
  • Water Saving: The product is designed to be water-efficient, contributing to reduced water consumption.
  • First Use: Before first use, it is recommended to flush the water pipes for at least 2 minutes to remove any impurities.
  • Safety Precautions:
    • Always ensure that all connections are correctly sealed to prevent leaks.
    • Do not use the product if any parts are damaged.
    • Avoid using abrasive or corrosive cleaning agents.
    • Ensure that the water supply is turned off before performing any maintenance or installation work.
    • For households with children, it is advised to supervise them during showering to prevent accidents.
    • If the water pipes are not properly flushed, impurities can damage the cartridge.
    • In case of damage to the shelf, ensure that there are no water pipes where you are intending to drill.

Maintenance Features

  • Cleaning:
    • Use only soft cloths and mild, non-abrasive cleaning agents (e.g., soap solution) to clean the chrome-plated surfaces.
    • Avoid using aggressive, corrosive, or alcohol-based cleaning agents, as these can damage the surface.
    • Regularly clean the shower nozzles to prevent limescale buildup.
    • For stubborn limescale, use a mixture of water and vinegar, then rinse thoroughly with clean water.
  • Cartridge Maintenance: The thermostatic cartridge is a wear part and should be checked every 1-2 years. If the water flow is significantly reduced or if the temperature control becomes erratic, the cartridge may need to be replaced.
  • Seal Checks: Regularly check all connections and seals for leaks or visible damage. Replace any damaged seals or connection hoses immediately.
  • Filter Cleaning: If the water pressure decreases, check and clean the filters in the angle valves and the thermostatic mixer.
  • Dismantling for Cleaning: The manual provides instructions for dismantling the product for thorough cleaning if necessary.
  • Winterization: In areas prone to freezing temperatures, ensure that the water supply to the shower is turned off and the pipes are drained to prevent frost damage.

eisl DX12008 Specifications

General IconGeneral
Brandeisl
ModelDX12008
CategoryPlumbing Product
LanguageEnglish

Related product manuals