www.elationlighting.com
16 MIDIcon™ User Manual
LED CONTROL
The following messages can be sent to MIDIcon™ by the software to control the states of
the LEDs and displays.
The MIDIcon™ will control the LEDs and page displays on power up. As soon as any valid
LED control message is received, MIDIcon™ will defer all LED control to external software.
Playback Page Display – Continuous Controller 10 or Continuous Controller 12
If using continuous controller 10, the MIDI channel will set the page number 1-16,
If using continuous controller 12, the value byte will set the page number to 0-99.
Continuous controller 10 will also set the playback’s MIDI channel; continuous controller 12
will only change the display. Continuous controller 12 can only use MIDI channel 1.
Memory Page Display – Continuous Controller 11 or Continuous Controller 13
If using continuous controller 11, the MIDI channel will set the page number 1-16,
If using continuous controller 13, the value byte will set the page number to 0-99.
Continuous controller 11 will also set the playback’s MIDI channel; continuous controller 13
will only change the display. Continuous controller 13 can only use MIDI channel 1.
Blackout LED – Note 28 or 89
Note 28 will also set the blackout state flag, 89 will only set or clear the LED. Use MIDI channel 1.
Playback LEDs –
For playbacks 1 through 8; use notes 31, 34, 37, 40, 43, 46, 49, 52, these are the same as the
“C” row of buttons. Use MIDI channel 1.
Touchpad LEDs – Notes 1 through 12 (same notes as the pads).
Use MIDI channel 1.