Multi_ING_Man_GenioSFERAE_03
GENIO-SFERA.E Radio remote control system
- Page 4 -
• Automatic switching off
: this option can be programmed using transmitter micro-switch 1 (OFF=active, see
diagram). Automatic switching off is activated if no commands are executed after approx. 3 minutes.
• External battery exhausted indication: When channels V and Z are not being used for transmission, it is
possible to activate a relay when Low-Battery is signalled by setting micro-switch 2 of the transmitter in the OFF
position. Relay V activates the low-battery signal on the receiver if micro-switch 2 is set to the ON position, if in
the OFF position, the signal is activated by the Start and Alarm relays.
• Programming the frequency: two different methods of programming frequency can be selected using micro-
switch 8 of the transmitting and receiving modules.
Setting of the manual frequency (micro-switch 8 set to ON). Sets the operating frequency in a fixed manner by
way of micro-switches 4, 5, 6 and 7.
Setting the Automatic frequency (micro-switch 8 to OFF). Makes it possible to use various pre-set operating
frequencies. The automatic frequency change is made using a particular sequence of commands.
Automatic frequency change. Procedure for changing the frequencies automatically – activating the Stop
command while the Start command is still activate , the operating frequency changes according to the automatic
frequency change sequence given in the table below. A subsequent Start command varies the operating
frequency from the previous one.
Note: The automatic frequency change option cannot be used in some versions of the GENIO-P.E model.
Microswitches
High part
frequency
7
6
5
4
3
Automatic
frequency
change
sequence
Automatic
frequency
per part nr.
434.075 0
0
0
0
0 1 Exxxx0
434.150 0
1
0
0
0 5
434.175 1
0
0
0
0 9 Exxxx5
434.225 1
1
0
0
0 13 Exxxx7
434.250 0
0
0
1
0 2
343.300 0
1
0
1
0 6 Exxxx3
434.325 1
0
0
1
0 10
434.400 1
1
0
1
0 14 Exxxx8
434.425 0
0
1
0
0 3 Exxxx1
434.525 0
1
1
0
0 7
434.550 1
0
1
0
0 11 Exxxx6
434.600 1
1
1
0
0 15
434.625 0
0
1
1
0 4 Exxxx2
434.725 0
1
1
1
0 8 Exxxx4
434.750 1
0
1
1
0 12
434.775 1
1
1
1
0 16 Exxxx9
Frequency table
CAUTION: Micro-switch 3 is for reserved use and must always remain set to OFF.