AN_BFT-200_EN_110216
HandsfreeintercomBFT-200
Doorreleasebutton
Speakon/off
Microphone
Speaker
Lightbutton
Mute&MuteSpeech
JumpersJP1-3
Microphonecontrol
Rotarycodingswitch
Terminalclamps
PushedIn
PushedIn
PushedIn
PulledOut
PulledOut
PulledOut
JP1
JP2
JP3
ButtoninternalcalltoaddressF/FButtoninternalcalltoaddressF/E
Buttons+lightanddoorreleasefunction(Factorysetting)
Noforwardingofstoreycalls(Factorysetting)
Fullduplexspeechmode
Forwardingofstoreycallstoparalleladdressedintercoms
Halfduplexspeechmode(push-to-talk)
Jumper
Funktion
a a b
R
Description
Terminalclamps
JumperKonfiguration
i2-BUSterminal(both “a” terminalsconnectedinternally)
Terminaltothestoreycallbutton(oppositepoletoi2-bus “a” or “b”)
Thesensitivityofthemicrophonecanbechangedwiththemicrophonecontrol.Ifthedoorstationcanonlybe
heardchoppily,reducethesensitivity.Ifthepersonwhoisspeakingcanonlybeheardchoppily,increasethe
sensitivity.(Factorysetting:middlelevel)Ifnosatisfyingsettingcanbefound,setthedevicetohalfduplex
speechmode.
Listeningandspeakingareautomaticallyswitchedbetweeninfullduplexspeechmode. Theswitchingisbe
dependantonthevolumeandcharacteristicofthespeechsignal.Listeningandspeakingareswitchedusingthe
buttoninhalfduplexspeechmode(push-to-talk). Theoperatorcanspeakwhenthebuttonispressed;the
conversationpartnercanbeheardwhenitisreleased. Theconnectionisendedbypressingthebutton.
Pressandholdthebuttoninidlemode.3ringtonevolumescanbeselectedwiththebutton.
Theringtonelastusedwillalwaysbechanged.Pressthebutton.
Thedesiredringtonecanbeselectedwiththebutton.
Rotarycodingswitchforadressconfiguration
Microphonecontrol
Full/halfduplexspeechmode
Settheringtonevolume
Settheringtone
Black: Groupaddress0-F(SettingofthecorrespondingBTE-116)
Blue:Intercomaddress0-F(TerminalofthecorrespondingdoorbellbuttononBTE-116)
A maximumof3intercomswiththesameaddresscanbeinstalled(paralleloperation)!
1
R
a
a
b
40
110
2
Hotline: hotline@elcom.de
Technicaladditionsandprintingerrorsdonotconstitutegroundsforanyclaimstodamages.
Connectingtheconductor:
Detachingthewire:
Simply
plugintheconductor.
(Solidconductordiameter
0.4-0.8mm)
Actuatetheorangetrigger.
Pullthewireout.
Detachthelockingmechanismwithascrewdriver
andslidethelidofthehousingupwards
Removetheconnectioncable
inthelowerpartofthehousing.
Mountthebaseofthehousing
andconnectupthesupplyline.
Installation:
Art.Nr.:0221102