EasyManua.ls Logo

elddis Buccaneer - Troubleshooting

elddis Buccaneer
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-15
ARRIVING ON SITE
Troubleshooting
In case of an error message, check the caravan stands are not too high at the front (front wheel
must be withdrawn), whether the battery has sufficient voltage, whether the oil level is correct,
whether there is any damage to the jacks, and check all the cables.
If this does not lead to a solution for the fault, the fault could be located in the drive units. As the
drive unit does not have any repairable parts, you should contact your E&P Hydraulics dealer/
installer.
Under normal circumstances, all LED’s are off and the unit will only respond by pressing the
button “ON/OFF” (no.5) switching the levelsystem on.
Problem Possible Causes Solution(s)
The system fails to start Battery voltage low. Recharge the battery, Charger
is defective or there is no
voltage being supplied.
The red battery lamp
lights up.
When the red battery
lamp lights continuously,
the installation is switched
off for 4 minutes.
The support jacks do not Oil level too low or no oil Check for any oil-leaks
extend towards the ground in the system.
when the pump is running.
The pump is not working Repair or exchange.
correctly.
There is no or bad electronic Check cables for loss of
connection. voltage.
The system does not work Caravan stands too high on Withdrawn the front wheel.
automatically, lamp front the front side.
wheel lights up.
**NOTHING works, even no Possible cause: the battery is
LED signal. fully out of order (<5V).
IMPORTANT: For all other reports and/or malfunctioning of the system, please contact
your dealer/installer.

Table of Contents

Related product manuals