What to do if the pump will not run in my elddis Crusader Motorhomes?
H
hmosesJul 27, 2025
If the pump does not run, you can try the following:
* Ensure at least one tap is open.
* Turn the pump isolation switch off and on again.
* Check the battery condition.
* Verify the mains isolator switch is on.
* Confirm the pump isolator switch is on.
* Inspect the contacts in the plug and socket to ensure they are clean and making contact.
* Check wiring connections.
* Check the fuse (see fuse box).
L
Luis BurnettAug 6, 2025
Why does the pump cycle on and off with all taps and shower closed in my elddis Crusader Motorhomes?
D
Donald WilliamsAug 6, 2025
The pump cycling on and off when all taps and the shower are closed could be due to air or water leaks in the taps and piping. Check that the non-return valve in the socket is free from grit by pushing a suitable blunt object, for example, a ballpoint pen, into the socket nipple against the non-return valve, holding the valve open to dislodge trapped grit. Alternatively, recalibrate the system.
S
Sheila FreemanAug 15, 2025
What to do if the pump motor runs steadily and does not stop after 30-40 seconds in my elddis Crusader?
J
Julie PetersAug 15, 2025
If the pump motor runs steadily and doesn't stop after 30-40 seconds, check all connections in the pipework. Also, recalibrate the system.