9-20
HOW TO USE YOUR CARAVAN’S EQUIPMENT
BATTERY CHARGER
The battery charger for the caravan battery will
automatically switch on when the caravan is
connected to a mains supply. The battery charger
will also provide a 12V supply to the caravan
when a battery is not connected. Please note that
the battery charger fitted is designed to keep
your battery charged and is not designed for
charging up a flat battery.
SMOKE DETECTOR
The caravan smoke detector will become active
once the 9V battery which should be supplied
with the smoke detector is connected. The
smoke detector fitted to your caravan has an
alarm pause mode which will reduce the
sensitivity of the alarm for a short period to
allow for cooking within the caravan. The alarm
pause mode is activated by pressing the button
marked HUSH on the smoke detector. While the
detector is in the pause mode the detector will
beep once per minute to alert that the alarm
pause mode is activated.
CARBON MONOXIDE DETECTOR
Your FireAngel detector offers many features
which set it apart from other CO detectors on
the market today.
Test/Reset button feature
This button will:
•Test the sounder, power pack and circuitry.
• Allows you to test the sensor by introducing
a source of CO into the detector.
• Silence the loud 85dB (at 1 metre (3 feet))
sounder during an alarm (only for alarms due
to levels of CO of less than 50ppm).
Testing the sounder, power pack and
circuitry
Test the sounder, power pack and circuitry by
pressing and releasing the Test/Reset button to
confirm that the detector is operating properly.
The sounder should sound as soon as the button
is pressed, and the Alarm LED will illuminate red
indicating that the sounder is working and the
power pack is providing power to the unit. This
test for the sounder, battery and circuitry should
be performed on a weekly basis.