13
For rooms with a volume greater than 10 m
3
- no permanent
ventilation is required.
Pay attention: Regardless of room size, all rooms containing
the appliance must have direct access to the outside air via an
openable window or equivalent.
Emptying of the Burned Gases from Environment
Cooking appliances that operate with gas, throw the burned gas
wastes out directly to the outside or through the cooker hoods
that are connected to the a chimney that opens directly to the
outside. If it seems not possible to install a cooker hood, it is
required to set an electric fan on the window or wall that has
access to fresh air. This electric fan must have the capacity to
change the air of the kitchen environment 4-5 times of its own
volume of air per hour.
Cooker hood
ue
Electrical ventilator
Air inlet section
minimum
100cm
2
Air inlet section
minimum
100cm
2