PART-2: INSTALLATION AND PREPARATIONS
FOR USE
This modern, functional and practical cooker, that has been
manufactured with parts and materials of the highest quality, will
meet your cooking needs in every aspect. You should read this
manual to avoid a problem and to achive satisfactory results.
The following information details correct installation and service
processes. It must be read especially by the technician who
will install the appliance.
Important: This appliance must be installed by a qualied
person according to the manufacturers installation
instructions, local building regulations, gas authority codes and
electrical wiring instructions.
2.1 Ventilation requirements
For rooms with a volume of less than 5 m
3
- permanent ventilation
of 100 cm
2
free area is required.
For rooms with a volume of between 5 m
3
and 10 m
3
a permanent
ventilation of 50 cm
2
free area will be required unless the room
has a door which opens directly to outside air, in which case
no permanent ventilation is required.
Air inlet section
minimum 100cm
2
Air inlet section
minimum 100cm
2