Remove any lint and dust around the machine.
7.4 Fresh air intake
At regular basis, check that the fresh air intake on the back of the machine is not clogged by lint and dust or otherwise
blocked.
Clean if necessary.
7.5 Machines with residual moisture control (RMC)
At regular basis, wipe off/clean drum and lifters with citric acid (Acidum citricum). If soap/softener residue remains, it
is recommended also to use a coarse sponge.
Lack of cleaning can affect the functionality of the residual moisture control. This can result in more moist load than
requested at program end.
7.6 Maintenance to be carried out by qualified service personnel
Contact qualified service personnel to perform the following maintenance:
After 1600 hours of operation or once a year, whichever comes first:
Clean the fan, the exhaust duct and the fresh-air intake to the room
On machines with RMC: Clean the glide surface on the RMC graphite collector
Clean the area around the drum
Clean the fan wheel
Clean the motors
Check the belt tension