EasyManua.ls Logo

Electrolux Beam Alliance - Muffler Installation; Optional HEPA Filter Installation

Electrolux Beam Alliance
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
1.5 Muffler Installation
1. To install the muffler on the power unit, connect one end of the short 90° elbow to the muffler as
indicated in Figure 5.
2. Glue the opposite end of the short 90° elbow to the WIDE open end of the long pipe adaptor.
Before connecting the short 90° elbows and long pipe adaptor, con rm the direction of the
intake  ange located on the bottom, back of the power unit. Ensure the muffler is located on the
opposite, OPEN end, of the intake  ange as illustrated in Figure 5. Otherwise, the muffler will
interfere with the pipe intake.
3. Connect both the long pipe adaptor and muffler assembly to the back of the power unit, securing
the muffler with the Torx 20 screws provided.
NOTE: DO NOT glue the muffler pipe adaptor to the central vacuum unit.
1.6 Optional HEPA Filter Installation
1. To properly install the optional HEPA  lter, secure the 90° elbow to the body of the HEPA  lter with
the Torx 20 screw provided.
Figure 5
Figure 6a