EasyManua.ls Logo

Electrolux EACM-09 HR/N6 - User Manual

Electrolux EACM-09 HR/N6
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER’S MANUAL
EACM-09 HR/N6
EACM-12 HR/N6
Question and Answer IconNeed help?

Do you have a question about the Electrolux EACM-09 HR/N6 and is the answer not in the manual?

Summary

Parts Description

Front view

Description of the front view of the air conditioner unit.

Rear view

Description of the rear view of the air conditioner unit.

Control Panel

TEMP. indicator

Explanation of the temperature indicator on the control panel.

Function buttons

Details and operation of the function buttons on the control panel.

Before starting the unit

Instructions for preparing the unit before initial operation.

Heating operation mode

Steps to operate the unit in heating mode.

Cooling operation mode

Steps to operate the unit in cooling mode.

Drying operation mode

Steps to operate the unit in drying mode.

Fan operation mode

Steps to operate the unit in fan mode.

Auto-restart function

Explanation of the auto-restart function of the air conditioner.

Accessories

Mobile air-conditioner air louver notes

Specific notes regarding the air louvers on mobile air conditioners.

Unpacking Inspection

Procedure for inspecting the unit after unpacking.

Safety Principles for Installing Air Conditioner

Key safety guidelines for the installation of the air conditioner.

Installation

Select a best location

Guidance on choosing the optimal placement for the air conditioner.

Duct mount instruction

Instructions on how to install the exhaust duct.

Install the Window Slider Kit

Step-by-step guide to installing the window slider kit.

Install the exhaust duct into the window

Procedure for connecting the exhaust duct to a window.

Install the exhaust duct into the wall

Procedure for connecting the exhaust duct to a wall.

Water drainage

Clean the unit

Clean the Air Filter

Troubleshooting

Air Condition Will Not Operate

Troubleshooting steps for when the air conditioner does not operate.

Unit Doesnt Start When Pressing ON;OFF Button

Troubleshooting steps for the unit not starting after pressing the ON/OFF button.

The Wind Blowing Out, But The Cooling; Heating Effect Is Bad

Troubleshooting poor cooling or heating effect when the unit is blowing air.

Noise or vibration

Troubleshooting issues related to noise or vibration from the unit.

Qualification requirements of maintenance personnel

Required qualifications for personnel performing maintenance.

Inspection of the Site

Procedures for inspecting the installation site before maintenance.

Operating Procedures

General guidelines for operating procedures during maintenance.

Inspection of Cable

Guidelines for inspecting the power cable for wear and damage.

Leakage check of R290 refrigerant

Procedure for checking refrigerant leaks in a safe environment.

Removal and Vacuum Pumping

Steps for removing refrigerant and vacuum pumping the system.

Procedures of Charging Refrigerants

Guidelines for safely charging refrigerants into the system.

Scrap and Recovery

Recovery

Detailed steps for recovering refrigerant from the appliance.

Specifications

Recycling

Information on how to properly recycle the appliance.

Warranty

Details on the warranty period, coverage, and terms for the product.

Date of manufacture

Information on how to find and interpret the date of manufacture.

Overview

This document is the user's manual for the Electrolux portable air conditioner models EACM-09 HR/N6 and EACM-12 HR/N6.

Function Description

The Electrolux portable air conditioner is designed for indoor use, offering cooling, heating (for HR/N6 models), drying, and fan-only operation modes. It utilizes R290 flammable refrigerant. The unit features a control panel with buttons for power, filter reset, fan speed, temperature adjustment, mode selection, sleep mode, and timer functions. It also includes an auto-restart function that restores the last used settings after a power interruption.

Important Technical Specifications

Models: EACM-09 HR/N6, EACM-12 HR/N6 Refrigerant Type: R290a for both models Capacity (cooling/heating):

  • EACM-09 HR/N6: 8870/7850 Btu/h
  • EACM-12 HR/N6: 11600/9210 Btu/h Input (cooling/heating):
  • EACM-09 HR/N6: 1000/790 Wt
  • EACM-12 HR/N6: 1300/1000 Wt Power Supply: 220-240V~50Hz for both models Current (cooling/heating):
  • EACM-09 HR/N6: 4.4/3.5 A
  • EACM-12 HR/N6: 5.8/4.6 A Indoor Side Noise Level: 65 dB(A) for both models Energy Efficiency Class: A for both models Size of Device (W×H×D): 476×710×385 mm for both models Package Size (W×H×D): 545×885×435 mm for both models Net/Gross Weight:
  • EACM-09 HR/N6: 32.5/37.5 kg
  • EACM-12 HR/N6: 33.5/38.5 kg Working Temperature Range:
  • Cooling mode: 16~35°C (60~95°F)
  • Heating mode: 5~27°C (41~80°F) Room Space Requirement: The room space for installation, use, repair, and storage must be greater than 12m². Refrigerant Charge Limit: Cannot charge more than 250g. Fuse Specification: AC 250V/5A (printed on the circuit board).

Usage Features

Control Panel: Features a digital display (TEMP. indicator) and multiple buttons:

  • Power (ن): Turns the unit on or off.
  • Filter Reset ( ): Illuminates after 250 hours of operation, indicating the air filter needs cleaning. Pressing it clears the light and resets the timer.
  • Fan Speed ( ): Selects fan speed (auto, high, medium, low). Not available in auto fan speed for fan mode.
  • Temperature Adjustment (+/-): Adjusts the setting temperature from 16°C (60°F) to 32°C (90°F) in 1°C/°F increments. Pressing both simultaneously for >3s toggles between Celsius and Fahrenheit.
  • Mode ( ): Cycles through operating modes: auto, cool, dry, fan, heat (heat-pump type). Cool-only units do not have a heating function.
  • Sleep Mode ( ): Enters sleep mode for 8 hours, then reverts to previous status. Not available in fan and dry modes.
  • Timer ( ): Sets an off-timer when the unit is on, or an on-timer when the unit is off. The display shows remaining time.
  • Swing ( ): Illuminates the swing indicator light, activating the automatic wind sweep function.

Operating Modes:

  • Heating Mode (HR/N6 models only): Set desired temperature and fan speed.
  • Cooling Mode: Set desired temperature and fan speed.
  • Drying Mode: Fan runs at a fixed low speed; temperature and fan speed cannot be adjusted. Windows and doors should be closed for optimal dehumidifying.
  • Fan Operation Mode: Select fan speed; temperature cannot be adjusted.

Water Drainage:

  • Dehumidifying Mode: Requires manual drainage by removing the upper drain plug and attaching a drain hose.
  • Water Full Indicator: "PI" symbol and "WATER FULL" light illuminate when the bottom tray is full. The unit needs to be moved to a drain location, the bottom drain plug removed, and the water drained.
  • Pump Drain Outlet (if equipped): For continuous drainage, remove the pump drain plug and attach a drain hose.

Installation:

  • Location: Flat, spacious area, at least 50cm clearance from walls/obstacles. Gradient should not exceed 10 degrees. Not for use in laundry rooms.
  • Exhaust Duct: Required for cooling, heating, and drying modes. Can be installed in a window (using a window slider kit) or through a wall (using a wall exhaust adaptor). The duct can be compressed (min 270mm) and extended (max 1500mm) but should be kept as short as possible and not excessively stretched or bent for optimal efficiency.
  • Electrical Connection: Must be plugged into a properly installed and grounded individual socket. Do not use extension cords or plug adaptors.

Maintenance Features

Cleaning the Unit:

  • Exterior: Clean gently with a wrung towel using tepid water (below 40°C/104°F).
  • Safety Precaution: Always shut down the unit and cut off electricity for at least 5 minutes before cleaning to avoid electric shocks.
  • Prohibited Cleaners: Do not use gasoline, benzene, thinner, other chemicals, or liquid insecticides, as these can damage paint and plastic parts. Do not pour water directly onto the unit.

Cleaning the Air Filter:

  • Removal: Remove the upper and lower air filters. Some models may require removing a screw for the low air intake grille.
  • Cleaning: Use a vacuum cleaner or rinse with water. For very dirty filters, use warm water (below 40°C/104°F) with mild detergent.
  • Drying: Dry the filter in the shade.
  • Reinstallation: Reinstall the dried filter in reverse order of removal.
  • Filter Reset Indicator: The "Filter Reset" light ( ) will illuminate after 250 hours of operation, prompting filter cleaning.

Long-Term Storage: If not using the unit for a long time, drain any inside water by pulling out the rubber plug.

Troubleshooting: The manual provides a table of possible causes and solutions for common issues like the unit not operating, poor cooling/heating effect, or noise/vibration.

Refrigerant System Maintenance (R290):

  • Qualified Personnel: Maintenance and repair involving R290 refrigerant must be performed by specially trained and qualified personnel.
  • Safety Precautions: Strict safety measures are outlined, including site inspection for flammable hazards, use of appropriate refrigerant detectors, fire extinguishing equipment, anti-static precautions, and ensuring adequate ventilation.
  • Leak Detection: Electronic leak detection instruments suitable for R290 must be used.
  • Refrigerant Recovery and Charging: Detailed procedures for safe removal, vacuum pumping, and charging of R290 refrigerant are provided, emphasizing the use of inert gases (oxygen-free nitrogen) and specialized equipment.

Warranty: The product comes with a two-year warranty from the purchase date, covering defects in materials and workmanship. The warranty is voided by misuse, poor maintenance, unauthorized repairs, or failure to follow manual instructions. Support is available through the dealer.

Recycling: The time-expired appliance should not be disposed of with household waste and must be collected separately according to local regulations (2012/19/EU directive).

Electrolux EACM-09 HR/N6 Specifications

General IconGeneral
BrandElectrolux
ModelEACM-09 HR/N6
CategoryAir Conditioner
LanguageEnglish

Related product manuals