4 Solutions To Common Problems
lee Dispenser
Problem Cause
Dispenserwill - Watersupplyisnotconnected.
not dispenseice.
Icedispenseris
jammed.
Icestoragecontaineris empty.
. Freezertemperatureissettoo
warm.
, Householdwaterlinevalve is
notopen.
° Freezerdoor isnot closed.
° Icedispensingarm hasbeen
heldin for morethan4-5
minutes.
ice hasmeltedandfrozen
aroundaugerdueto infrequent
use,ternperaturefluctuations,
and/orpoweroutages.
Icecubesarejammedbetween
icemakerand backof ice
container.
Icecubesarefrozentogether.
Correction
Connectwatersupply (seeConnectingThe
WaterSupplysection).
o Ensureice makeristurnedon. Whenthefirst
supplyof iceisdropped intothecontainer,the
dispensershould operate.
Turnfreezercontrol toa highersetting so that
icecubeswill bemade.Whenfirst supplyof ice
ismade,dispensershould operate.
Openhouseholdwater linevalve.Allow
sufficienttime for the iceto bemade.Whenice
is made,the dispensershouldoperate,
Ensurefreezerdoor isclosed=(SeeProblem
Section,Opening/Closingof Doors/Drawers)
Motor is overloaded.Motor overloadprotector
will resetin approximately3 minutes,icecan
then bedispensed.
Removeice container,thaw,and emptythe
contents.Cleancontainer,wipe dry,and replace
inproperposition.Whennewiceis made,
dispensershould operate.
. Removeice cubesthat arejammingthe
dispenser.
Icecubesarehollow or smaller
than normal.
Usethe dispenseroftenso that cubesdo not
freezetogether.
Theice & waterfilter cartridgecould be
clogged.Replacethefilter cartridge.Dispensing
systemoperatesbestat 30-100psiwater
pressure.Wellwater pressuresshould fall
within this range.
Water Dispenser
Problem
Dispenserwitl
not dispense
water.
Waterhasan
oddtaste and/or
odor.
Ceuse
o Watersupplyis notconnected.
- Householdwaterlinevalveis
notopen.
- Freezerdoor isnot closed.
o Ice&water filter cartridgeis
clogged.
o Frontfilter notfully installed,if
equipped
Waterhasbeeninthe tankfor
a periodof time.
Unitnot properlyconnectedto
coldwater line.
Tubingusedinthe household
water supplyandinstallation
mayaffectwater tasteand
odor.
o Waterhasa highmineral
content.
Correction
Connectwatersupply (seeConnectingThe
WaterSupplysection).
Openhouseholdwater linevalve.SeeProblem
sectionIceMakerIs NotMaking Ice.
Ensurethatfreezerdoor isclosed.(SeeProblem
Section,Opening/Closingof Doors/Drawers)
Replacefilter cartridge.
Pushfilter in untilyou heartwo "clicks". Filter
should beflush with cabinet.
Drawanddiscardt0-12 glassesof waterto
freshenthe supplyandcompletelyrinse outthe
tank.
Connectunitto cold waterlinethat supplies
waterto the Htchenfaucet.
Forbestresults,usecoppertubingforwater
connections.
Contactwatertreatmentplantfor helpin
checkingwater supplysource.
Waterpressureis
extremelylow.
Cut-offandcut-on pressures
aretoo tow(weltsystems
only).
o Reverseosmosissystemis in
regenerativephase.
Havesomeoneturn upthecut-off andcut-on
pressureonthewater pumpsystem (well
systemsonly).
It is normalfor a reverseosmosissystemto be
below20psi duringthe regenerativephase.

Related product manuals