installation Requirements
Clearance requirements
INSTALLATION IN A RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom,
recess or closet, MUST be exhausted outdoors.
2. No other fuel burning appliance shall be
installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid
door.
.
Closet door ventilation required: A minimum
of 120 square inches (774.2 cm 2)of opening,
equally divided at the top and bottom of the
door, is required. Openings should be located
3 inches (7.6 cm) from bottom and top of door.
Openings are required to be unobstructed
when a door is installed. A Iouvered door with
equivalent air openings for the full length of the
door is acceptable.
3"
i (7-6cm)
3"
i(7,6cm)
closet door
f
60 sq. in.
(387.1cm 2)
MINIMUM INSTALLATION CLEARANCES -Inches (cm)
SIDES REAR TOP FRONT
Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a
Under-
0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a
Counter
Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.5 cm)
For other than straight back venting, a quick-turn 90°
dryer vent elbow must be installed to achieve 0" (0 cm)
ii
ii
II
0"41 I#
(Ocm) ol