Suitable isolation devices include, for ex-
ample, circuit breakers, fuses (screw type
fuses are to be removed from the holder),
RCDs and contactors.
Anti-shock protection must be provided by
the installation.
The built-in unit must meet the stability re-
quirements of DIN 68930.
Built-in cookers and cooking surfaces are
equipped with special attachment sys-
tems. For safety reasons, they must only
be combined with appliances from the
same manufacturer.
The use of heat protection strips is prohibited
for cookers and ovens with Pyrolytic Clean-
ing, if the recess has a rear wall and closed
ground-level compartment.
However installation is possible with a
ground-level compartment that has been
shortened by at least 20 mm and which has
base ventilation of the same cross-section.
720 mm
560 mm
320 mm
320 mm
40 mm
551 mm
364 mm
90°
90°
2x
15x
2x
electrolux 19