Problem Possible cause Solution
DEMO appears on the dis‐
play.
The appliance is in dem‐
onstration mode.
Keep the Mode pressed for
approximately 10 seconds
until a long sound is heard
and display shuts off for a
short time.
Door is misaligned or inter‐
feres with ventilation grill.
The appliance is not lev‐
elled.
Refer to "Levelling".
There is not enough car‐
bon dioxide in the water.
The carbon dioxide is
running out.
Refer to "Installation of the
gas cylinder".
The incoming water pres‐
sure is too low.
Drain off a large amount of
carbonated water (about 1 li‐
tre).
There is too much carbon
dioxide in the water.
Dilute with ordinary water.
(See "The functions of the
water dispenser" in "Opera‐
tion" chapter).
Dilute with ordinary wa‐
ter.
Refer to "Selecting and dis‐
pensing water".
No carbon dioxide. The gas cylinder is emp‐
ty.
Refer to "Replacing gas cyl‐
inder".
No or very low water flow. The gas cylinder is emp‐
ty.
Refer to "Replacing gas cyl‐
inder".
Sediment in the water. Remove and clean the
strainer in the inlet hose con‐
nection.
Water supply obstructed. Check water supply.
Only gas comes out when
dispensing carbonated wa‐
ter.
Sediment in the water. Remove and clean the
strainer in the inlet hose con‐
nection.
Dispensing is interrupted
after a short time.
The maximum time of
two minutes is exceeded.
Start new dispensing.
The "Water circuit clean‐
ing" and "Still cold water"
indicators are shown.
No water has been dis‐
pensed in 10 days.
Dispense water in total 2 mi‐
nutes and the icons goes off.
The buzzer sounds. The
"Alarm" icon and "Extra
Humidity" icons are flash‐
ing.
Failed water supplies. "Press any button to reset
the alarm. Select still cold
water and push the water
dispensing lever and re‐
lease. The water pump start
and filling the water system.
After a few minutes the icons
goes off.
www.electrolux.com36