PROBLEM POSSIBLE CAUSES SOLUTION
Motor will not start or suddenly stops Unit not connected to power source Push plug securely into outlet
Try another outlet or check circuit breaker
Check plug and cord for damage
Switch not turned on Press power switch to ‘carpet’ or ‘bare oor’ setting
Themal cut-off has operated Correct the cause of motor overheating. See thermal cut-off information
No suction. Vacuum cleaner does not pick
up lint or dirt
Blockage in air path Remove any obstructions that restrict airow through hose and valve
clean out areas #1 & #2
Dust cup full Empty dust cup
Dust Cup Filter clogged Remove and clean lter.
Fine dust can block the airow through the lter and reduce suction even
if dust cup does not look full
Hepa Filter clogged Remove and clean lter
Dust Cup Filter not in place Filter must be in lter frame for correct performance
Make sure lter frame is installed properly in lter cover for dust cup as-
sembly to t back into place
Switch not on proper setting Use ‘carpet’ setting for carpetted oors
Use ‘bare oor’ setting for hard-surfaced oors and when using acces-
sories
* Turbo nozzle clogged (selected models only) Remove and clean debris from turbo nozzle
Dust cup will not lock into vacuum cleaner Dust Cup Filter not in place Locate dust cup lter and insert into dust cup
Quick Release handle will not lock into
vacuum cleaner
Telescopic wand is extended Place end of wand into opening at back of vacuum and align ribs into
grooves
Red “Reset” indicator light is on Object caught in brush roll Unplug vacuum, remove debris and threads from brush roll. Depress red
brush roll reset button, plug in unit, and continue.
Use ‘bare oor’ setting when vacuuming fringe of rugs
Check brush roll for threads and debris. Clean if needed
Brush roll not positioned properly Make sure both ends of brush roll are free of debris and secured properly
so roll can rotate freely
Brush roll not operating properly
Note: ”Check brush roll” indicator light turns
on when brush roll is not turning. Brush roll
motor will shut off to prevent damage to motor.
Brushroll will not turn Using brushroll clean pedal on high pile rug/carpet Move unit to bare oor, push reset button. Operate normally
TROUBLESHOOTING
For your safety, turn vacuum cleaner off and unplug power cord before
attempting to resolve problems.
Note: Any servicing of the vacuum other than described in this manual shall only be performed by an authorized service representative.