DGS-TDS-N 05.2006 © Electrolux 7 168 650
Fault Possible cause Remedy
Insufficient
temperature
difference top/bottom
Cooling temperature
too cold
Temperature setting
Sealing lip missing from false floor
False floor missing
Heating defect
Air flap control defective
Air flap jams
Sensors exchanged
Set correctly
Fit sealing lip
Mount false floor
Inspect heating (see Diagnosis.
Replace if defect)
Inspect servomotor (see diagnosis)
Remedy air flap malfunction
Connect sensor correctly
Formation of
condensation on the
door
Increased atmospheric moisture Wipe off with a dry cloth, set a little
warmer.
Error message F1 on
the operation panel
Top sensor defect
(Appliance does not function in the
emergency programme)
Replace sensor (see 6.3.11).
Error message F2 on
the operation panel
Bottom sensor defect
(Appliance does not function in the
emergency programme)
Replace sensor (see 6.3.11).