Penta
- Programming Worksheet
(00) COMMUNICATION ATTEMPTS
Communication Rounds
1-F (F=unlimited rounds)
Dialing Attempts
1-F
(01) SYSTEM PARAMETERS
____,____,____,____,____
Fifth Digit:
P Key Alarm
0 - Audible
1 - Silent
First Digit:
Keypads
0 - No Keypads
1 - One Keypad
2 - Two Keypads
3 - Three Keypads
Third Digit: Tamper Zone Definition
0 - Arm/Disarm Keyswitch
1 - Tamper Zone
Second Digit: Keyswitch Function
0 - Latching
1 - Momentary
Fourth Digit:
E Key Alarm
0 - Audible
1 - Silent
(02) COMMUNICATION PARAMETERS
____,____,____,____,____
Fifth Digit: Dialing
0 - Pulse
1 - DTMF
First Digit: Protocol
0 - 20pps 4/2 no parity
1 - Follow Me
2 - Contact ID
3 - Voice Message (3601)
4 - 10pps 3/1 no parity
Fourth Digit:
Handshake
0 - 1400Hz Handshake
1 - 2300Hz Handshake
Second Digit: RP Access Type
0 - Passcode
1 - Callback
Third Digit: RP Access
0 - Disable RP Access
1 - Enable RP Access
ZONE DEFINITIONS
(03) __,__ Zone 1 (04) __,__ Zone 2
(05) __,__ Zone 3 (06) __,__ Zone 4
TIMERS
(07) __,__h Entry Delay (1-255 Sec) PGM OUTPUT FUNCTION
(08) __,__h Exit Delay (1-255 Sec) (10) __,__
(09) __,__ Bell Cut-Off (1-5 Min)
00 - PGM Disabled
01 - Armed/Disarmed Status
02 - Entry/Exit Tone Follower
04 - Communication Status
08 - AC Loss/Restore
10 - Bell Follower
20 - Duress
40 - Alarm
00 - Perimeter with Delay (Silent)
10 - Perimeter with Delay (Audible)
01 - Perimeter (Silent)
11 - Perimeter (Audible)
02 - Conditional (Silent)
12 - Conditional (Audible)
03 - Interior (Silent)
13 - Interior (Audible)
04 - 24hr (Silent)
14 - 24hr (Audible)
05 - Fast Loop Perimeter (Silent)
15 - Fast Loop Perimeter (Audible)