1
MS-6115 Multifunction Power Meter Instructions
Please read the following instructions carefully before connecting this meter to electrical appliances.
WARNING!
Do not plug two or more meters together!
Indoor use only!
Not position the energy meter so that it is difficult to disconnect it from the supply!
IMPORTANT
Don't plug in an appliance where the load exceeds 10 Amp. Always ensure the plug of any appliance is fully inserted into the meter
outlet. If cleaning of the meter is required, remove from mains power and wipe meter with a dry cloth.
KEYBOARD DEFINITION
1. MASTER CLEAR: Clear all data in memory including current time and all programs.
2. UP: Set current time, price, price programs combined with buttons SET; exchange 12-24 hour mode during clock display state.
3. SET: Set current time, price, price programs combined with buttons UP.
4. FUNC: Exchange display state.
GENERAL FEATURES
1. Display current clock.
2. Display line voltage.
3. Display line current.
4. Display line power.
5. Display and memory accumulative total electric quantity.
6. Display and memory total on time and total electric charge,.
7. Display and memory total on time and total electric charge of price1.
8. Display and memory total on time and total electric charge of price2.
9. Display line frequency.
10. Display power factor.
11. Adjustable price / kWh
11 combinations of day or blocks of days available as follows:
MO
TU
WE
TH
FR
SA
SU
MO,TU, WE, TH, FR
MO,TU, WE, TH, FR, SA
SA, SU
MO, TU, WE, TH, FR, SA, SU
BATTERY
Insert the 3 pcs battery(LR44/AG13) according to the correct direction indication, close the cover of battery.Press master clear
button after insert battery.now the power meter is now ready to be set up for use.
Note: 1. The cover must be in place before use.
2. The battery must be taken out if not use for long time.
THE DATA DISPLAY
Press FUNC button the data displays as follows:
VOLTac AMP WATT KWh TOTAL PRICE;TOTAL ON TIME PRICE1 PRICE2
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
1.The meter will display current clock and line voltage, frequency, if plug in socket after insert battery without any operation.
2. Press FUNC button once and release, the meter will display current clock and line current, power factor.
3. Press FUNC button once again and release, the meter will display current clock and real power, power factor.
4. Press FUNC button once again and release, the meter will display current clock and accumulative KWh,power factor.
5. Press FUNC button once again and release, the meter will display total on time and total electric charge.
6. Press FUNC button once again and release, the meter will display total on time of price 1 and total electric charge of price 1.
7. Press FUNC button once again and release, the meter will display total on time of price 2 and total electric charge of price 2.
8. Press FUNC button once again and release, the meter will come back to display current time and line voltage.
Press and hold FUNC button for 5 seconds to clear accumulative total electric quantity and total electric charge during display
state of total electric charge or total electric charge of price 1 or total electric charge of price 2.
9. LCD display ----when total electric quantity, total electric charge overflow, the OVER will flash at the same time.
SETTING CURRENT CLOCK
1. Press FUNC button until the CLOCK displays in LCD.
Question and Answer IconNeed help?

Do you have a question about the Electus Distrubution MS-6115 and is the answer not in the manual?

Electus Distrubution MS-6115 Specifications

Power IconPower
power supply240V AC 50Hz
max load10A, 2400W
power cost<0.5W
Measurement Ranges IconMeasurement Ranges
measure voltage range200-276V AC
measure current range0.01-10A
measure power range0.2W-2760W
Measurement Accuracies IconMeasurement Accuracies
measure voltage accuracy+/-1%
measure current accuracy+/-1% or +/-0.01 A
measure power accuracy+/-1% or +/-0.2W
Frequency and Time IconFrequency and Time
measure frequency range45-65Hz
clock accuracy+/- 1 minute per month
operating temperature-10°C to +40°C
Battery IconBattery
battery type3x1.5V LR44/AG13
battery lifeabout 3 months without AC power

Summary

Keyboard Definition

MASTER CLEAR Function

Clears all memory data, including current time and programs.

UP Button Functionality

Sets time/price programs, switches between 12-24 hour clock modes.

SET Button Functionality

Sets time/price programs in conjunction with the UP button.

Battery Installation and Notes

Data Display and Operation

Setting the Current Clock

Setting Cost Price Per kWh

Setting Price 1

Enter cost per kWh, weekday, and ON TIME using SET and UP buttons.

Setting Price 2

Repeat the setting process for the second price and ON TIME.