Short circuit - red LED lights up when worked electro-fisher
protection. The number of flashes indicates the type of failure
(error that occurred). Detailed information about problem is
visible on LCD.
Error no. 1 Anode and cathode short circuit type 1
(metallic no. 1)
Error no. 2 Temperature inside is above 90°C
Error no. 3 Sparks appears at battery clamp
Error no. 4 No High Voltage on output (contact service)
Error no. 5 Anode and cathode short circuit type 2
(during switch on)
Error no. 6 Anode and cathode short circuit type 3
(anode and cathode too close)
Error no. 7 Anode and cathode short circuit type 4
(metallic no. 2)
Error no. 8 Safety problem (High Voltage present on
electro-fisher casing)
Error no. 9 Processor Hung-up
Error no. 10 Safety problem (Water inside electro-fisher)
Error no. 11 Input Voltage above 15V
Error no. 12 No impulses on MOSFET 1 (contact service)
Error no. 13 No impulses on MOSFET 2 (contact service)
Error no. 14 Weak battery or battery sulphated
Error no. 15 MOSFETs conduct (contact service)
Error no. 16 Thyristor Conduct (contact service)
Error no. 17 Comparator have got wrong voltage level
(possible water inside)
Error no. 18 MOSFET gate 1 problem (contact service)