AEROSPRAY
®
HEMATOLOGY STAT
MODEL 7122
Applications
Manual
SLIDE STAINER/CYTOCENTRIFUGE

Table of Contents

Questions and Answers

  • J
    Jordan BellAug 5, 2025
    Why is there smear separation or tearing with my ELITechGroup Laboratory Equipment?
    • L
      Lisa MillerAug 5, 2025
      Smear separation or tearing with ELITechGroup Laboratory Equipment can occur due to several reasons. First, ensure proper alcohol fixation by verifying the alcohol nozzle's spray pattern and volume. If you suspect fixation failure, pre-fix specimen slides in methanol before loading. Also, select a fixation setting that increases fixation. Wet smears can also lead to this problem, so allow smears to dry for several minutes before staining. The use of new, premium quality slides is highly recommended. Finally, ensure the methanol used for fixing is anhydrous; replace if necessary.
  • M
    Mr. Andrew MooreAug 13, 2025
    What to do if I see red cell artifacts with ELITechGroup AEROSPRAY 7122 Laboratory Equipment?
    • G
      gwatsonAug 13, 2025
      If you observe red cell artifacts when using ELITechGroup Laboratory Equipment, it might be due to water contamination in the methanol used for fixing smears. To resolve this, ensure that the methanol is free of water. If you're uncertain, replace it with a reagent known to be anhydrous.
  • J
    jacksonkennethAug 20, 2025
    How to prevent smear separation due to dirty slides with ELITechGroup AEROSPRAY 7122?
    • K
      Karl KingAug 20, 2025
      If you are experiencing smear separation or tearing while using ELITechGroup Laboratory Equipment, make sure that you are using new, premium quality slides.
  • W
    Wayne GutierrezAug 28, 2025
    How to prevent smear separation due to wet smears with ELITechGroup AEROSPRAY 7122 Laboratory Equipment?
    • R
      robertsjasonAug 28, 2025
      To prevent smear separation or tearing with ELITechGroup Laboratory Equipment, ensure that smears are adequately dry before commencing a stain cycle. Allow the smears to dry for several minutes.

Summary

Section 1 Introduction

1.1 Instrument Overview

Provides instructions to install, operate, and maintain the Aerospray Hematology Stat Stainer/Cytocentrifuge.

Section 3 Controlling and Customizing Stainer Functions

3.1 System Setup Menu

Allows control over various software settings like stain programs, user accounts, and language.

Section 5 Preventive Maintenance and Safety

5.1 Preventive Maintenance

Details daily, weekly, and monthly maintenance tasks and logging procedures for the instrument.

5.2 Storing the Instrument

Outlines the long-term storage procedure to prevent nozzle clogging and instrument damage.

5.3 Replacing Fuses

Provides instructions and warnings for safely replacing the instrument's fuses.

5.4 Cleaning the Stainer and Carousels

Explains cleaning procedures for the instrument, carousels, and handling spills or broken slides.

5.5 Decontaminating the Stainer and Carousels

Details decontamination procedures for the instrument and reagent bottles, emphasizing safety.

5.6 Shipping or Disposing of the Stainer or Carousels

Covers decontamination, hazard-free certification, and proper disposal methods for the instrument.

Section 6 Nozzle Maintenance and Performance

6.1 Nozzle Disassembly and Cleaning

Step-by-step guide for disassembling, cleaning, and reassembling instrument nozzles.

6.2 Nozzle Reassembly

Instructions for reassembling disassembled nozzle components after cleaning.

6.3 Manual Priming

Procedure for manually priming reagent lines using a priming tool.

6.4 Performing the Volume Test

Guide for conducting the weekly Volume Test to check nozzle spray volumes.

6.5 Performing the Slide Pattern Test

Instructions for performing the Slide Pattern Test to check nozzle performance.

Section 7 Solving Problems

7.1 Troubleshooting

A general troubleshooting table to identify and solve routine instrument problems.

7.2 Abnormal Staining Results

Discusses common issues causing abnormal staining and their solutions.

7.3 Instrument Malfunction

Addresses issues like air/reagent leaks and reagent level detect system errors.

7.4 Calibrating the Touchscreen

Steps to calibrate the instrument's touchscreen for accurate input.

7.5 Service Information

Contact information for ELITechGroup support and service.

Section 8 Cytopro Cytocentrifuge

8.1 Cytopro Cytocentrifuge Information

Details the functionality and features of the Cytopro Cytocentrifuge rotor.

Appendix A Critical Reagent Components

Appendix B Risk and Safety Phrases

Appendix C Accessories and Supplies

ELITechGroup AEROSPRAY 7122 Specifications

General IconGeneral
BrandELITechGroup
ModelAEROSPRAY 7122
CategoryLaboratory Equipment
LanguageEnglish