ES 50 – ES 80
14
6 Technical data ES 50 – ES 80
Operative range
Application for…
Parking area, parking garage
Company entrance
Safety area
Drive pulse from…
Push-button, card reader, key switch, desk top panel etc.
remote control
Induction loop
Safety
Reversing on obstacle
Best protection against vandalism
Ergonomic emergency release
Table 1
General data
Mains supply 230V / 50Hz
Max. current 10A (max.)
Duty cycle 100%
Ambient temperature range
-20°C to +70°C
Storage temperature range
-20°C to +70°C
Relative humidity max. 95%, non-condensing
Controller MO 63
Measurements (w/l/h) 400x450x1.100mm
Foundation (frost-proofed) 600x650x800mm
Boom connector central
Housing aluminium
Mechanical parts steel, zinc coated
Sound pressure level (distance 1m) ≤ 60 dB(A)
Degree of protection IP 44
Table 2

Table of Contents