Model Number | LKAV3021 |
---|---|
Material | Stainless Steel |
ADA Compliant | Yes |
Chilled Water | Yes |
Bottle Filling Sensor | Yes |
Refrigerant Type | R134a |
Water Temperature (Chilled) | 50°F |
Bottle Counter | Optional |
Drain Connection | 1-1/4" |
Electrical Requirements | 115V, 60Hz, 1Ph |
Place the faucet assembly through the mounting hole in sink before installation.
Align gasket and deck plate with sink hole, place faucet assembly through them.
Hand-tighten nut onto faucet assembly, then lock into position with screws.
Thread supply line nut onto the water supply valve outlet and tighten with a wrench.
Remove aerator, turn on water, check for leaks, then replace aerator.
Turn off water, remove handle, loosen set screw, and unscrew cap from cartridge nut.
Loosen cartridge nut, lift out old cartridge, insert new one, and reinstall handle.
Covers defects in materials and workmanship for original consumer purchaser.
Contact Elkay with purchase date, defect description, and model number.