What to do if the centrifuge lid is left open on Elmi Laboratory Equipment?
- NNoah SilvaAug 5, 2025
If the Elmi Laboratory Equipment centrifuge lid is left open, close it and press down until you hear a click.
What to do if the centrifuge lid is left open on Elmi Laboratory Equipment?
If the Elmi Laboratory Equipment centrifuge lid is left open, close it and press down until you hear a click.
What to do if there is residual rotation of the rotor due mains power failure in Elmi CM-8S Laboratory Equipment?
If you experience a residual rotation of the rotor in your Elmi Laboratory Equipment due to a mains power failure, wait until the rotor stops moving. Ensure that there isn't a power failure.
How to fix no display on Elmi Laboratory Equipment?
If there is no mains power or display on the screen of your Elmi Laboratory Equipment, check the connection of the power cable.
What to do if control buttons are stuck on Elmi CM-8S?
If one of the control buttons ('OPEN', 'START/STOP') is stuck on your Elmi Laboratory Equipment, check the buttons to ensure they are not physically stuck.
How to fix total imbalance of test tubes in Elmi CM-8S Laboratory Equipment?
To resolve a total imbalance of test tubes in your Elmi Laboratory Equipment, insert the test tubes symmetrically on opposite sides and ensure they are filled to the same weight. Each test tube should be counterbalanced by another test tube.
Detailed technical parameters including speed, RCF, timer, noise, and environmental conditions.
List of all items included in the centrifuge package, such as the main unit, power cord, and user manual.
Covers general usage safety, electrical connection safety, and precautions during operation to prevent hazards.
Guidelines for safe handling of biological materials, including prohibitions and recommended practices.
Guide on adjusting essential parameters like speed, time, and braking levels via the touchscreen interface.
Explanation of the main operating menu, its display, and the parameters that can be modified.
Steps to create, name, save, and view custom centrifugation programs.
Guide to accessing and modifying advanced centrifugation parameters.
Instructions on how to lock or unlock user-created programs for modification.
Procedure to select and set the desired display language for the centrifuge interface.
Adjusting the volume of sound signals and the brightness of the centrifuge display.
Accessing centrifuge information, viewing total operating time, and restoring factory settings.
Details on password protection for service engineers and technicians.