What to do if the centrifuge lid is left open on Elmi CM-7S Plus Laboratory Equipment?
- SsharpkennethAug 16, 2025
If the Elmi Laboratory Equipment centrifuge lid is left open, close it and press down until you hear a click.
What to do if the centrifuge lid is left open on Elmi CM-7S Plus Laboratory Equipment?
If the Elmi Laboratory Equipment centrifuge lid is left open, close it and press down until you hear a click.
How to fix no display on Elmi CM-7S Plus Laboratory Equipment?
If there is no mains power or display on the screen of your Elmi Laboratory Equipment, check the connection of the power cable.
What to do if control buttons are stuck on Elmi CM-7S Plus Laboratory Equipment?
If one of the control buttons ('OPEN', 'START/STOP') is stuck on your Elmi Laboratory Equipment, check the buttons to ensure they are not physically stuck.
How to fix total imbalance of test tubes in Elmi Laboratory Equipment?
To resolve a total imbalance of test tubes in your Elmi Laboratory Equipment, insert the test tubes symmetrically on opposite sides and ensure they are filled to the same weight. Each test tube should be counterbalanced by another test tube.
How to fix black screen on Elmi Laboratory Equipment?
If your Elmi Laboratory Equipment's screen is black, it's likely due to a lack of main power or a power failure. Ensure the power cable is properly connected.
What to do if Elmi Laboratory Equipment shows disbalance?
If your Elmi Laboratory Equipment shows a disbalance error, it's because the total imbalance of test tubes exceeds 7 grams. To resolve this, ensure you load the rotor symmetrically.
Why Elmi Laboratory Equipment says the lid is not shut?
If the lid of your Elmi Laboratory Equipment isn't shut, it means the centrifuge lid is open. Close the lid and press down until you hear a click.
Why does my Elmi CM-7S Plus Laboratory Equipment say 'Please wait cooling down'?
If your Elmi Laboratory Equipment displays 'PLEASE WAIT COOLING DOWN', it indicates that the Processor Control Board is overheated. Allow some time for the centrifuge to cool down automatically.
What to do if there is residual rotation of the rotor due mains power failure in Elmi CM-7S Plus Laboratory Equipment?
If you experience a residual rotation of the rotor in your Elmi Laboratory Equipment due to a mains power failure, wait until the rotor stops moving. Ensure that there isn't a power failure.
What to do if Elmi CM-7S Plus Laboratory Equipment rotor is spinning?
If the rotor is spinning in your Elmi Laboratory Equipment, it's due to residual rotation. Simply wait until the rotor comes to a complete stop.
Details the technical specifications of the CM-8S centrifuge, including speed, force, timer, and environmental conditions.
Lists the items included in the centrifuge package, such as the centrifuge, power cord, rotor, and user manual.
Covers general safety guidelines and specific electrical safety measures for operating the centrifuge.
Details biological safety measures, especially when handling hazardous materials and microorganisms.
Guides on setting speed, time, and braking levels using the standard menu.
Instructions on setting rotor speed, time, and braking levels via the touchscreen interface.
Information on creating and saving custom centrifugation programs on the centrifuge.
Covers the correct methods for installing rotors, including securing them with a nut and key.
Provides guidance on loading rotors symmetrically and counterbalancing test tubes to prevent imbalance.
Outlines regular checks for housing, parts, bearings, and engine condition.
Guides on cleaning and disinfecting the centrifuge and its accessories to prevent damage and contamination.