Do you have a question about the Elmo SSA-12/55 and is the answer not in the manual?
Channels | 2 |
---|---|
Impedance | 8 ohms |
Frequency Response | 20Hz - 20kHz |
Signal-to-Noise Ratio | 80dB |
Input Impedance | 47k ohms |
Power Output | 12W per channel |
Contains information, cautions, and warnings for safe operation and retention of instrument condition.
Highlights hazards related to parts removal, live adjustments, and conductor interruption.
Covers amplifier protection mechanisms: short circuit, under/over voltage, and temperature faults.
Details MOSFET capability for short circuit protection and inhibit indication.
Explains amplifier inhibition when DC bus voltage exceeds specified limits.
Describes amplifier inhibition due to heatsink temp >90°C, with auto-restart.
Lists power stage (Vs, M1, M2, G) and control stage (1-12) terminals with their functions.
Offers techniques for proper wiring, grounding, and shielding for servo operation and performance.
Instructions for adjusting balance trimmer (T2) to stop motor when the command signal is zero.
Details measuring current limits using a load and terminal 7 current monitor with its scale.