Details the different code combinations for power supply and outputs.
Explains the function and types of signals for OUT1 to OUT5.
Describes setpoint control methods and adjustment locking features.
Covers thermocouple, RTD, linear error, and ambient temperature influence.
Details control outputs, setpoint inputs, process outputs, and serial interface.
Lists permissible operating conditions, power supply, and casing details.
Explains the PROCESS and SET display areas on the controller.
Describes the function of LEDs and the Parameter (P) and Enter (E) keys.
Outlines the three main operating levels: Operating, Parameter, and Configuration.
Explains how to move between levels and return to the operating level.
Details settings for controller type, including heating/cooling modes and step control.
Configures the behavior and signal type for outputs OUT1, OUT2, OUT4, and OUT5.
Lists available sensors (Thermocouple, RTD) and their temperature ranges.
Covers decimal points, display range limits, and analogue input limitations.
Defines alarm conditions and switching behavior for output 3.
Describes alarm conditions and switching behavior for output 2.
Explains the general function and purpose of softstart for heating applications.
Details parameters for softstart ratio, setpoint, and duration.
Describes how to operate the controller manually as an actuator.
Explains configuration for external analogue setpoint signals on R1300-3.
Defines behavior during sensor break for 3-point-step controllers.
Covers parameter locking and serial interface configuration like address and data format.
Details parameters for limiting the output ratio for heating and cooling.
Explains proportional band (P), rate (D), and reset (I) parameters for control action.
Describes how to set the cycle time for different output types.
Covers switch-point difference, PID parameters, and sensitivity for heat-cool operation.
Explains how to start the automatic tuning process for controller parameters.
Covers proportional band, reset time, sensitivity, and dead band for 3-point controllers.
Sets the motor actuating time for actuators in 3-point step control.
Details how to apply an offset to the process value for calibration and error correction.
Describes the use of Setpoint 1 and Setpoint 2, including activation via external contact.
Explains how to configure rising and falling ramps for setpoint changes.
Lists common error codes, their causes, and suggested solutions.
Covers intended use, protection, and environmental considerations for installation.
Emphasizes regulations, cable separation, shielding, and mains connection safety.
Stresses the importance of expert configuration before initial operation.
| Category | Controller |
|---|---|
| Processor | ARM Cortex-M4 |
| RAM | 128 KB |
| Flash Memory | 512 KB |
| Power Supply | 24 VDC |
| Ethernet | 10/100 Mbps |