Manual: R1300-X-00-X_EN Release: 1.04 © Elotech GmbH Page 1/20
R 1300
Multifunctional Controller
DIN-Format: 96 x 96 mm
Installation depth: 122 mm
Description and Operating Manual
ELOTECH Industrieelektronik GmbH
Verbindungsstrasse 27
D 40723 HILDEN
FON +49 2103 / 255 97 0 FAX +49 2103 / 255 97 29
www.elotech.de Email: info@elotech.de
Question and Answer IconNeed help?

Do you have a question about the Elotech R 1300 and is the answer not in the manual?

Summary

Type Code Identification

Understanding the Type Code

Details the different code combinations for power supply and outputs.

Connection Diagram and Outputs

Output Signal Configurations

Explains the function and types of signals for OUT1 to OUT5.

Setpoint and Adjustment Lock

Describes setpoint control methods and adjustment locking features.

Technical Specifications

Input and Sensor Data

Covers thermocouple, RTD, linear error, and ambient temperature influence.

Output and Interface Capabilities

Details control outputs, setpoint inputs, process outputs, and serial interface.

Operating Conditions and Power

Lists permissible operating conditions, power supply, and casing details.

Display and Keyboard Interface

Display Screen Layout

Explains the PROCESS and SET display areas on the controller.

Status Indicators and Keys

Describes the function of LEDs and the Parameter (P) and Enter (E) keys.

Controller Operating Levels

Navigating Operating Levels

Outlines the three main operating levels: Operating, Parameter, and Configuration.

Level Transition and Return

Explains how to move between levels and return to the operating level.

Configuration Level Details

Controller Configuration Options

Details settings for controller type, including heating/cooling modes and step control.

Output Module Configuration

Configures the behavior and signal type for outputs OUT1, OUT2, OUT4, and OUT5.

Sensor and Input Configuration

Sensor Type and Range Selection

Lists available sensors (Thermocouple, RTD) and their temperature ranges.

Input Signal and Range Settings

Covers decimal points, display range limits, and analogue input limitations.

Alarm Configuration Settings

Alarm 3 (OUT 3) Behavior

Defines alarm conditions and switching behavior for output 3.

Alarm 2 (OUT 2) Behavior

Describes alarm conditions and switching behavior for output 2.

Softstart Functionality

Softstart Operation Modes

Explains the general function and purpose of softstart for heating applications.

Softstart Parameter Settings

Details parameters for softstart ratio, setpoint, and duration.

Manual Mode and Setpoint Selection

Manual Output Control

Describes how to operate the controller manually as an actuator.

External Setpoint Input

Explains configuration for external analogue setpoint signals on R1300-3.

Communication and System Settings

Sensor Break Handling

Defines behavior during sensor break for 3-point-step controllers.

Adjustment Lock and Interface Setup

Covers parameter locking and serial interface configuration like address and data format.

Parameter Level: Output and PID Control

Output Ratio Limiting

Details parameters for limiting the output ratio for heating and cooling.

PID Control Tuning Parameters

Explains proportional band (P), rate (D), and reset (I) parameters for control action.

Actuator Cycle Time

Describes how to set the cycle time for different output types.

Parameter Level: Heat-Cool Control Tuning

Heat-Cool PID and Sensitivity Settings

Covers switch-point difference, PID parameters, and sensitivity for heat-cool operation.

Automatic Self-Tuning Function

Initiating Self-Tuning

Explains how to start the automatic tuning process for controller parameters.

Parameter Level: 3-Point Step Control

3-Point Step PID and Dead Band

Covers proportional band, reset time, sensitivity, and dead band for 3-point controllers.

Motor Actuating Time

Sets the motor actuating time for actuators in 3-point step control.

Process Value Offset Adjustment

Correcting Process Value Readings

Details how to apply an offset to the process value for calibration and error correction.

Operating Level: Setpoints and Ramps

Primary and Secondary Setpoints

Describes the use of Setpoint 1 and Setpoint 2, including activation via external contact.

Setpoint Ramp Programming

Explains how to configure rising and falling ramps for setpoint changes.

Error Displays and Troubleshooting

Error Codes and Remedies

Lists common error codes, their causes, and suggested solutions.

XI. Installation Instructions

General Installation Guidelines

Covers intended use, protection, and environmental considerations for installation.

Electrical Connection Safety

Emphasizes regulations, cable separation, shielding, and mains connection safety.

Pre-Operation Configuration

Stresses the importance of expert configuration before initial operation.