SITINGTHEUNIT
Thecylindermustbeverticallyoormounted.
Althoughlocationisnotcritical,thefollowingpoints
shouldbeconsidered:
Thecylindershouldbesitedtoensureminimum•
deadlegdistances,particularlytothepointof
mostfrequentuse.
Avoid siting where extreme cold temperatures •
willbeexperienced.Allexposedpipework
shouldbeinsulated.
Thedischargepipeworkfromthesafetyvalves•
musthaveminimumfallof1:200fromtheunit
andterminateinasafeandvisibleposition.
Access to associated controls and immersion •
heatersmustbeavailabletoprovideforthe
servicingandmaintenanceofthesystem.
Wherethesecontrolsareinstalledagainstawalla
minimumdistanceof250mmmustbeleft(see
Fig.1).
Ensurethattheoorareaforthecylinderislevel•
andcapableofpermanentlysupportingthe
weightwhenfullofwater.(seeTable1)
WATERSUPPLY
Bear in mind that the mains water supply to the
propertywillbesupplyingboththehotandcold
waterrequirementssimultaneously.
It is recommended that the maximum water
demand is assessed and the water supply
checked to ensure this demand can be
satisfactorily met.
Note: A high mains water pressure will not
always guarantee high ow rates.
Whereverpossiblethemainssupplypipeshould
be22mm.Wesuggesttheminimumsupply
requirementsshouldbe0.15MPa(1.5bar)pressure
and20litresperminuteowrate.However,at
thesevaluesoutletowratesmaybepoorif
severaloutletsareusedsimultaneously.Thehigher
theavailablepressureandowratethebetterthe
systemperformance.
Thecylinderhasanoperatingpressureof0.35MPa
(3.5bar)whichiscontrolledbythecoldwater
combinationvalveassembly.Thecoldwater
combinationvalveassemblycanbeconnectedtoa
maximummainspressureof1.6MPa(16bar).
OUTLET/TERMINALFITTINGS(TAPS,ETC.)
Thecylindercanbeusedwithmosttypesofterminal
ttings.Itisadvantageousinmanymixershowers
tohavebalancedhotandcoldwatersupplies.In
theseinstancesabalancedpressurecoldwater
connectionshouldbeplacedbetweenthe2pieces
ofthecoldwatercombinationvalveassembly(see
Fig.2).Outletssituatedhigherthanthecylinderwill
giveoutletpressureslowerthanthatattheheater,a
10mheightdifferencewillresultina0.1MPa(1bar)
pressurereductionattheoutlet.Allttings,pipework
andconnectionsmusthavearatedpressureofat
least0.6MPa(6bar)at80°C.
GENERAL REQUIREMENTS
Table1:Unitweights
Fig.1:SitingtheUnit