ABNORMAL
PROCEDURES
AIRPLANE
F
LIGHT
4-10 ANAC APPROVED
Page 6 code 01 REVISION 15
Copyright © by Embraer. Refer to cover page for details.
AC STANDBY BUS OFF
Monitor electrical system.
NOTE: Engine Start with batteries only is not available.
APU GENERATOR OFF BUS
Turn the APU generator off, then on.
If the APU GEN OFF message persists, turn the APU generator off.
BATTERY 1 (2) DISCHARGING
Select the affected TRU to off and then to auto.
If
the BATT 1 (2) DISCHARGING message persists, select the
affected TRU to off.
BATTERY 1 OFF
Verify battery 1 is set to on.
NOTE: If battery 1 selector is off, APU start is not available.
BATTERY 2 OFF
Verify battery 2 is set to auto.