ATA CHAPTER 06 DIMENSIONS AND AREAS
System & 1. 2. Number installed
Sequence ITEM 3. Number required for dispatch
Number 4. Remarks and/or exceptions
6 DIMENSIONS AND
AREAS
41-1 Exterior Main Door
Control Panel Access
Door
(123AL - Figure 1)
1 0 May be missing with no
penalty.
41-2 External Power
Connection Access
Door
(113EL - Figure 1)
1 0 May be missing with no
penalty.
41-3 Ground Air
Conditioning
Connection Access
Door
(191AR - Figures 3, 5)
1 0 May be missing provided
maximum airspeed is limited
to 250 KIAS/0.65 M,
whichever is lower.
41-4 Air Conditioning Heat
Exchanger Grills
(191ML - Figures 2, 4)
(191NR - Figures 3, 5)
2 0 May be missing provided
maximum airspeed is limited
to 250 KIAS/0.65 M,
whichever is lower.
41-5 Pack Valve/Wing Anti-
ice Valve Access Door
(191KL - Figure 2)
(191LR - Figure 3)
2 0 May be missing provided
maximum airspeed is limited
to 250 KIAS/0.65 M,
whichever is lower.
41-6 Bleed Flexible Joint
Access Door
(195AL/CL - Figure 2)
(194AR/CR - Figure 3)
4 0 May be missing provided
maximum airspeed is limited
to 250 KIAS/0.65 M,